Control of Lithium Ion Battery Charging and Discharging MM1248
Control of Lithium Ion Battery Charging and Discharging
Monolithic IC MM1248
Outline
This IC was developed for use in controlling charging and discharging of lithium ion batteries (battery modules
with three cells connected in series). In charging control, the voltage of the battery module as a whole is
controlled in constant-voltage control. Discharge control and monitoring of overvoltage rely on monitoring of
the voltages of individual cells.
Features
1. Charging control voltage
VBATH=12.465V±1.5% (Ta=-20°C~70°C)
2. Overcharge detection voltage
VCELL=4.335V±1.5% (Ta=-20°C~70°C)
3. Internal circuit for setting dead time (for overvoltage detection, discharge control)
4. Low consumption current on overdischarge IBATH3=1µA typ.
5. High-precision internal overvoltage detection startup circuit (cell voltage 4.2V or higher at end of charging)
Package
SOP-16B (MM1248XF)
Absolute Maximun Ratings (Except where noted otherwise, Ta=25°C)
Item
Storage temperature
Operating temperature
Input voltage
Charge voltage
Power supply voltage
Voltage applied to OV2 pin
Allowable loss
Symbol
TSTG
TOPR
VIN max.
VBAT max.
VCC max.
VO2 max.
Pd
Ratings
-40~+125
-20~+70
18
15
15
10
350
Units
°C
°C
V
V
V
V
mW

1 page




MM1248 pdf
MITSUMI
Control of Lithium Ion Battery Charging and Discharging MM1248
Circuit conventions
• Charge control unit
• Overcharge detection unit
Subtraction amp, buffer amp, voltage comparator, dead time setting circuit
• Discharge control unit
Cell voltage monitoring circuit, dead time setting circuit
• Overvoltage sensing (rough detection) unit
• High-precision reference voltage unit
Operating outline
1. Charge control
Charge control is turned on and off using the CON pin; when CON is low the charge control unit is in
operation. The error amp of the charge control unit takes inputs of 4.155V from the high-precision reference
voltage unit and the battery module voltage monitor output. The battery module voltage monitor outputs a
voltage equal to 1/3 the battery module voltage, so that in charging control the charging control FET (pin 2)
is controlled such that the battery module voltage is 4.155 3 V.
This block performs constant-voltage control only; current limiting (constant-current control) should be
implemented on the charging input side.
2. Overcharge detection
There are two blocks for overcharge detection; three output modes are provided according to input
conditions and cell voltage.
1. Charging signal on (during discharge)
2. Charging signal off (during discharge)
3. Discharge off
2-1. Charging signal on
The high-precision overcharge sensing unit is always in the operating state, and the voltage of each cell is
monitored.
In order to monitor each cell's voltage precisely, subtraction amps are provided for monitoring M and H cell
voltages, and a buffer amp is used to monitor the L cell voltage. By means of these amps the voltage of
each cell is converted to a GND-reference voltage, and compared with the high-precision reference voltage
of 4.335V.
If the voltage of any one of the cells exceeds 4.335V, the overvoltage is sensed, and the dead time setting
pin (CCC pin 7) is charged by a constant current; when the CCC pin is charged to the threshold voltage of
the dead time setting circuit (4.35V), an overvoltage signal is output.
(OV1 pin "H", OV2 pin "L")
When an overcharge signal is output, the overvoltage monitoring unit switches from the overvoltage state
to the reset monitoring state, and an overcharge signal is output until the voltages of all cells fall to 4.16 V.
To summarize the sequence of operations, when the voltage of any of the cells remains in the overcharge
state continuously for the specified time (the dead time), that cell is judged to be in an overcharged state
and is switched to overvoltage output; when all the cell voltages drop to the overcharge reset voltage or
below, the overcharge state is canceled.
On entering the overcharge state, if the charge control unit circuit is turned off, the latter unit will not
operate.
Pin
OV1
OV2
Output logic
Normal
Overvoltage
LH
High impedance
L
Output type
PNP output, internal pull-down resistance
NPN open-collector output

5 Page










PáginasTotal 8 Páginas
PDF Descargar[ Datasheet MM1248.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
MM1245(MM1xxx) System ResetMitsumi Electric
Mitsumi Electric
MM1248Control of Lithium Ion Battery Charging and DischargingMITSUMI
MITSUMI

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar