Datasheet CLE436 Equivalent ( PDF ) |
N.º | Número de pieza | Descripción | Fabricantes | Category |
1 | CLE436 | Minimal Infrared Content D ome Lens Can
CLE436
Preliminary High Power Red LED – Minimal Infrared Content Dome Lens Can, Hermetically Sealed
0.156 (3.96) 0.136 (3.45) 1.00 (25.4) min.
®
Clairex
March, 2006
Technologies, Inc.
0.100 (2.54) dia. 0.215 (5.46) 0.205 (5.21) ANODE
0.165 (4.19) 0.145 (3.68)
0.19 | Clairex | data |
2 | CLE436W | Minimal Infrared Content Flat Window Can
CLE436W
Preliminary High Power Red LED – Minimal Infrared Content Flat Window Can, Hermetically Sealed
0.156 (3.96) 0.136 (3.45) 0.165 (4.19) 0.145 (3.68) 1.00 (25.4) min.
®
Clairex
March, 2006
Technologies, Inc.
0.100 (2.54) dia. 0.215 (5.46) 0.205 (5.21) ANODE
0. | Clairex | data |
CLE Datasheet ( Hoja de datos ) - resultados coincidentes |
N.º | Número de pieza | Descripción | Fabricantes | Catagory |
1 | CLE-0922-400 | Chlorine Sensor Classic Line 4-Cl2-200 Sensor
Chlorine Sensor 0-200 ppm
Performance Characteristics
0BU
Part Number
CLE-0922-400
Nominal Range
0 to 200ppm
Sensitivity Baseline(20 oC)
0.18 ± 0.05 µA/ppm < ± 0.2 µA
Baseline Drift (-20 to 40 oC)
0 to -0.3 ppm equivalent
Resolution
0.1 ppm
Response Solidsense sensor | | |
2 | CLE230 | High Power Aluminum Gallium Arsenide IREDs
CLE230,CLE231,CLE232,CLE233
High Power Aluminum Gallium Arsenide IREDs
0.210 (5.33) 0.190 (4.83) 1.00 (25.4) min.
®
Clairex
February, 2001
Technologies, Inc.
0.100 (2.54) dia. 0.215 (5.46) 0.205 (5.21) ANODE
0.158 (4.01) 0.136 (3.45)
0.190 (4.83) 0.176 (4.47) CATHODE Clairex data | | |
3 | CLE231 | High Power Aluminum Gallium Arsenide IREDs
CLE230,CLE231,CLE232,CLE233
High Power Aluminum Gallium Arsenide IREDs
0.210 (5.33) 0.190 (4.83) 1.00 (25.4) min.
®
Clairex
February, 2001
Technologies, Inc.
0.100 (2.54) dia. 0.215 (5.46) 0.205 (5.21) ANODE
0.158 (4.01) 0.136 (3.45)
0.190 (4.83) 0.176 (4.47) CATHODE Clairex data | | |
4 | CLE232 | High Power Aluminum Gallium Arsenide IREDs
CLE230,CLE231,CLE232,CLE233
High Power Aluminum Gallium Arsenide IREDs
0.210 (5.33) 0.190 (4.83) 1.00 (25.4) min.
®
Clairex
February, 2001
Technologies, Inc.
0.100 (2.54) dia. 0.215 (5.46) 0.205 (5.21) ANODE
0.158 (4.01) 0.136 (3.45)
0.190 (4.83) 0.176 (4.47) CATHODE Clairex data | | |
5 | CLE233 | High Power Aluminum Gallium Arsenide IREDs
CLE230,CLE231,CLE232,CLE233
High Power Aluminum Gallium Arsenide IREDs
0.210 (5.33) 0.190 (4.83) 1.00 (25.4) min.
®
Clairex
February, 2001
Technologies, Inc.
0.100 (2.54) dia. 0.215 (5.46) 0.205 (5.21) ANODE
0.158 (4.01) 0.136 (3.45)
0.190 (4.83) 0.176 (4.47) CATHODE Clairex data | | |
6 | CLE435 | Aluminum Gallium Arsenide Dome Lens Can
CLE435
®
Preliminary Red LED, Aluminum Gallium Arsenide Dome Lens Can, Hermetically Sealed
0.156 (3.96) 0.136 (3.45) 1.00 (25.4) min.
Clairex
Technologies, Inc.
0.100 (2.54) dia.
March, 2001
0.165 (4.19) 0.145 (3.68)
0.215 (5.46) 0.205 (5.21) ANODE
0.190 (4.83) 0.17 Clairex data | | |
7 | CLE435W | Gallium Arsenide Phosphide Flat Window Can
CLE435W
®
Preliminary Red LED, Gallium Arsenide Phosphide Flat Window Can, Hermetically Sealed
0.156 (3.96) 0.136 (3.45) 0.165 (4.19) 0.145 (3.68) 1.00 (25.4) min.
Clairex
Technologies, Inc.
March, 2006
0.100 (2.54) dia. 0.215 (5.46) 0.205 (5.21) ANODE
0.190 (4.83) 0. Clairex data | |
Esta página es del resultado de búsqueda del CLE436. Si pulsa el resultado de búsqueda de CLE436 se puede ver detalladamente sobre la hoja de datos, el circuito y la disposición de pin. |
Número de pieza | Descripción | Fabricantes | |
SPS122 | Modern EU gaming Machines require increased +12V current to accommodate the latest gaming peripherals. DC Converters have been engineered with Sanken’s latest technology to efficiently convert redundant power from our lamp gaming PSU and provide additional +12V capacity at the point of use. |
Sanken |
DataSheet.es | 2020 | Privacy Policy | Contacto | Sitemap |