Multifunction Counter (DIN 72 × 72)
H7BX
CSM_H7BX_DS_E_4_4
DIN 72 × 72 mm Multifunction Counter with a
Bright, Easy-to-view, Negative Transmissive LCD.
• Highly visible display with backlit transmissive LCD.
• Selectable display color (red/green) enables checking output status at a
distance.
• Easy operation with a key for each digit.
• Perform all basic settings with a DIP switch.
• Provides a total and preset counter, batch counter, dual counter, and
tachometer (See note.).
• Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2-
wire DC sensors.
• Complies with UL, CSA, and CE marking.
• Degree of protection: IP54 equivalent (front section only).
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Note: The functions that can be selected depend on the model.
Refer to Safety Precautions on page 25.
Ordering Information
List of Models
External power supply
Output type
12 VDC
Contact and
NPN transistor output
Accessories (Order Separately)
Name
Soft Cover
Hard Cover
Terminal Cover *
Model
Y92A-72F1
Y92A-72
Y92A-72T
* Supplied with the H7BX.
Supply voltage
100 to 240 VAC
24 VAC/12 to 24 VDC
1-stage
H7BX-A
H7BX-AD1
2-stage
H7BX-AW
H7BX-AWD1
1

1 page




H7BX pdf
Connections
Terminal Arrangement
Confirm that the power supply meets specifications before using the H7BX.
H7BX-A
H7BX-AW
H7BX
0V
8 9 10 11 12 13 14
() External power supply (+)
Unused. 15
17 Unused.
Key
protection
16
OUT
OUT
18
1234567
H7BX-AD1
0V
8 9 10 11 12 13 14
()
Unused. 15
External power supply
(+)
OUT1 17
Key
protection
16
OUT2
OUT2 OUT1
18
1234567
H7BX-AWD1
0V
8 9 10 11 12 13 14
() External power supply (+)
Unused. 15
17 Unused.
Key
protection
16
OUT
OUT
18
1234567
() (+)
Note: Do not use the unused terminals for relay connections.
Block Diagram
Output circuit
(Basic insulation)
Power supply
circuit
(Basic insulation)
Input circuit
Internal control
circuit
Display circuit
Key switch
circuit
0V
8 9 10 11 12 13 14
()
Unused. 15
External power supply
(+)
OUT1 17
Key
protection
16
OUT2
OUT2 OUT1
18
1234567
() (+)
Input Circuits
CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input
+14 V
1 kΩ
IN
Internal
circuit
Note: The circuit shown above is for
no-voltage input (NPN input).
5

5 Page





H7BX arduino
H7BX
Explanation of Functions
Settings marked with a star can be performed with the DIP switch.
Input Mode (cntm)
Set increment mode (UP), decrement mode (DOWN), or one of the
increment/decrement modes (UP/DOWN A, UP/DOWN B, or UP/
DOWN C) as the input mode. Input modes other than UP or DOWN
modes cannot be set using the DIP switch. Use the operation keys if
other modes are required. (For details on the operation of the input
modes, refer to Input Modes and Present Value on page 13.)
Dual Count Calculating Mode (calm)
When the H7BX using as a dual counter, select either ADD (addition)
or SUB (subtraction) as the calculation method for the dual count
value.
ADD: Dual count value = CP1 PV + CP2 PV
SUB: Dual count value = CP1 PV CP2 PV
Output Mode (outm)
Set the way that control output for the present value is output. The
possible settings are N, F, C, R, K-1, P, Q, A, K-2, D, L, and H. Output
modes other than N, F, C, or K-1 cannot be set using the DIP switch.
Use the operation keys if other modes are required. The output
modes that can be set vary with the model. (For details on the
operation of the output modes, refer to Input/Output Mode Settings on
page 14.)
Reset Input Signal Width (iflt)
Set the reset input signal width (20 ms/1 ms) for reset/reset 1 and total
reset/reset 2 inputs together. If contacts are used for input signals, set
the counting speed to 20 ms. Processing to eliminate chattering is
performed for this setting.
Decimal Point Position (dp)
Decide the decimal point position for the present value, CP1/CP2
present values, set values (SV1, SV2), total count value, dual count
value and dual count set value.
Prescale Value (pscl)
Pulses input to the counter are converted according to the specified
prescale value.
Setting range: 0.001 to 99.999
Example: To display the feed distance for systems that output
25 pulses for a feed length of 0.5 m in the form @@.@@ m:
1. Set the decimal point position to 2 decimal places.
2. Set the prescale value to 0.02 (0.5 ÷ 25).
0.5 m
One-shot Output Time (otim)
Set the one-shot output time (0.01 to 99.99 s) for the control output.
A one-shot output can be used only when C, R, K-1, P, Q, A, or K-2
is selected as the output mode. Output times other than 0.5 s or 0.05
s cannot be set with the DIP switch. Use the operation keys if other
settings are required.
Encoder
25 pulses
One-shot Output 2 Time (otm2)
When the H7BX using as a 2-stage counter or batch counter, set the
one-shot output time (0.01 to 99.99 s) for control output (OUT2). A
one-shot output can be used only when C, R, K-1, P, Q, A, or K-2 is
selected as the output mode. Output times other than 0.5 s or 0.05 s
cannot be set with the DIP switch. Use the operation keys if other
settings are required.
One-shot Output 1 Time (otm1)
When the H7BX using as a 2-stage counter, set the one-shot output
time (0.01 to 99.99 s) for control output (OUT1). A one-shot output
can be used only when D, L, or H is selected as the output mode. If
the output time is set to 0.00, hold is displayed, and outputs are held.
Counting Speed (cnts)
Set the maximum counting speed (30 Hz/5 kHz) for CP1 and CP2
inputs together. If contacts are used for input signals, set the counting
speed to 30 Hz. Processing to eliminate chattering is performed for
this setting.
Note: Incorrectly setting the prescale value will result in counting
errors. Check that the setting has been performed correctly
before using the H7BX.
NPN/PNP Input Mode (imod)
Select either NPN input (no-voltage input) or PNP input (voltage
input) as the input format. For 2-wire sensors, set the format to NPN
input. The same format setting applies to all external inputs. For
information on input connections, refer to page 6.
Display Color (colr)
Set the color used for the present value.
Output OFF *
Output ON *
red Red (fixed)
grn Green (fixed)
r-g Red Green
g-r Green
Red
* When the H7BX using as a 2-stage counter, this is the status of
output 2.
Key Protect Level (kypt)
Set the key protect level.
For details, refer to Key Protect Level on page 24.
11

11 Page







PáginasTotal 27 Páginas
PDF Descargar[ Datasheet H7BX.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
H7BXMultifunction CounterOmron
Omron

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar