DataSheet.jp

CDP-TX-02ANP の電気的特性と機能

CDP-TX-02ANPのメーカーはCIRCUIT DESIGNです、この部品の機能は「UHF Narrow band radio data module」です。


製品の詳細 ( Datasheet PDF )

部品番号 CDP-TX-02ANP
部品説明 UHF Narrow band radio data module
メーカ CIRCUIT DESIGN
ロゴ CIRCUIT DESIGN ロゴ 




このページの下部にプレビューとCDP-TX-02ANPダウンロード(pdfファイル)リンクがあります。
Total 23 pages

No Preview Available !

CDP-TX-02ANP Datasheet, CDP-TX-02ANP PDF,ピン配置, 機能
OPERATION GUIDE
UHF Narrow band radio data module
CDP-TX/RX-02N 434 MHz/458MHz
Operation Guide
Version 1.6 (September 2003)
OG_CDP-02N_v16e
CIRCUIT DESIGN, INC.
7557-1 Hotaka, Hotaka-machi,
Minamiazumi, Nagano 399-8303 JAPAN
Tel: + +81-(0)263-82-1024
Fax: + +81-(0)263-82-1016
http://www.circuitdesign.jp

1 Page





CDP-TX-02ANP pdf, ピン配列
OPERATION GUIDE
GENERAL DESCRIPTION & FEATURES
Features
Compatible with European standard EN 300 220
• Very small compact integrated device with PLL synthesizer and micro controller
• Frequency selection free in 32 channels for 433 MHz, 11 channels for 458 MHz
• New integrated UHF filter technology
• 5 mW/10 mW selectable
Applications
Radio remote control cranes and machines
• Radio remote control for garage door controls
• Security systems
• Telemetry systems
Models
The CDP-02N series includes the following models;
Model name
CDP-TX-02N
CDP-RX-02N
CDP-TX-02AN
CDP-RX-02AN
CDP-TX-02NP
CDP-RX-02NP
CDP-TX-02ANP
CDP-RX-02ANP
Frequency
434 MHz
434 MHz
458 MHz
458 MHz
434 MHz
434 MHz
458 MHz
458 MHz
Base model
-
-
-
-
CDP-TX-02N
CDP-RX-02N
CDP-TX-02AN
CDP-RX-02AN
Ch setting
Dip switches
Dip switches
Dip switches
Dip switches
Pin connectors
Pin connectors
Pin connectors
Pin connectors
For CDP-TX/RX-02(A)N, frequency setting is performed with the 4-bit switches. Instead of
these 4-bit switches, CDP-TX/RX-02(A)NP have 8-pin connectors for frequency setting,
making it possible to set the channels externally.
There are no other technical and mechanical differences between CDP-02(A)N and CDP-
02(A)NP except the supply voltage of the TX.
Note:
Turn off the power of the module when setting the frequency channel of the transmitters
(CDP-TX-02(A)N and CDP-TX-02(A)NP). The status of each channel port will be read by the
CPU when power is turned on. It is not possible to change the channel setting while the
power is on.
For the receiver modules (CDP-RX-02(A)N and CDP-RX-02(A)NP), frequency setting and
channel change can be performed with the power turned on.
OG_CDP-02N_v16e
3 Circuit Design, Inc.


3Pages


CDP-TX-02ANP 電子部品, 半導体
OPERATION GUIDE
OPERATING INSTRUCTIONS
Please read these instructions before you start using the CDP-02N.
The CDP-02N is designed as a module which will be integrated into a user system. It is not a
ready-made product for private users. It can be regarded more like a special component for
part of an electronic system. The user needs basic knowledge about electronics. Special
knowledge about RF technology is helpful, but the most difficult parts are integrated into the
modules to enable easy operation. Some additional information is given here:
Supply voltage
The transmitter and receiver module contain a voltage regulator to guarantee stable
performance in the given range of supply voltage.
The design was made for operation with a battery or regulated power source. If the battery
voltage drops below the minimum voltage given in the technical specifications, the transmitter
output power will drop and the RF oscillator will stop operation. No data can be transmitted in
this case. The receiver will continue to work down to a certain voltage but the performance
will deteriorate.
If the voltage connected to the Vcc (+) and Ground (-) terminal is above the maximum voltage
given in the technical specification the internal voltage regulator will be permanently
damaged. The result is an internal short-circuit or disconnection.
To enable a low minimum voltage no internal circuit is used to prevent damage by incorrect
polarity. If the transmitter is connected incorrectly, it will be permanently damaged. If a higher
supply voltage is available then a simple diode can be inserted in the connection line to the
Vcc terminal to prevent damage by incorrect polarity. The diode must be rated for the
maximum supply current detailed in the technical specifications.
Modules which have been connected to improper voltage sources should be returned to the
dealer for inspection.
Data input
The data input terminal is connected to a digital transistor compatible input. Use of data
sources of high impedance is acceptable.
The voltage of the data signal should be between 0V (Ground level) and Vcc. Because of the
internal voltage regulator, it is recommended that the data high level be limited to 5 V.
The data can be an analog or digital signal. Analog signals will be converted to a digital 1 or 0
inside the transmitter.
It is not necessary to synchronize the data signal of the transmitter, but the data signal should
be fed to the transmitter 80 ms after the transmitter is turned on.
OG_CDP-02N_v16e
6 Circuit Design, Inc.

6 Page



ページ 合計 : 23 ページ
 
PDF
ダウンロード
[ CDP-TX-02ANP データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
CDP-TX-02AN

UHF Narrow band radio data module

CIRCUIT DESIGN
CIRCUIT DESIGN
CDP-TX-02ANP

UHF Narrow band radio data module

CIRCUIT DESIGN
CIRCUIT DESIGN


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap