DataSheet.es    


PDF HCF40194B Data sheet ( Hoja de datos )

Número de pieza HCF40194B
Descripción 4-BIT BIDIRECTIONAL UNIVERSAL SHIFT REGISTER
Fabricantes STMicroelectronics 
Logotipo STMicroelectronics Logotipo



Hay una vista previa y un enlace de descarga de HCF40194B (archivo pdf) en la parte inferior de esta página.


Total 12 Páginas

No Preview Available ! HCF40194B Hoja de datos, Descripción, Manual

HCC/HCF40104B
HCC/HCF40194B
4-BIT BIDIRECTIONAL UNIVERSAL SHIFT REGISTER
. MEDIUM-SPEED OPERATION : fCL = 9MHz
(typ.) @ VDD = 10V
. FULLY STATIC OPERATION
. SYNCHRONOUS PARALLEL OR SERIAL
OPERATION
. THREE-STATE OUTPUTS (HCC/HCF40104B)
. ASYNCHRONOUS MASTER RESET
(HCC/HCF40194B)
. STANDARDIZED, SYMMETRICAL OUTPUT
CHARACTERISTICS
. QUIESCENT CURRENT AT 20V FOR HCC DE-
VICE
. 5V, 10V, AND 15V PARAMETRIC RATINGS
. INPUT CURRENT OF 100nA AT 18V AND 25°C
FOR HCC DEVICE
. 100% TESTED FOR QUIESCENT CURRENT
. MEETS ALL REQUIREMENTS OF JEDECTEN-
TATIVE STANDARD N° 13A, ”STANDARD SPE-
CIFICATIONS FOR DESCRIPTION OF ”B”
SERIES CMOS DEVICES”
EY
(Plastic Package)
F
(Ceramic Package)
C1
(Plastic Chip Carrier )
ORDER CODES :
HCC401XXBF HCF401XXBEY
HCF401XXBC1
DESCRIPTION
The HCC40104B, HCC40194B, (extended tem-
perature range) and the HCC40104B, HCF40194B
(intermediate temperature range) are monolithic in-
tegrated circuits, available in 16-lead dual in-line
plastic or ceramic package and plastic micro pack-
age. The HCC/HCF 40104B is a universal shift reg-
ister featuring parallel inputs, parallel outputs, SHIFT
RIGHT and SHIFT LEFT serial inputs, and a high-im-
pedance third output state allowing the device to be
used in bus-organized systems. In the parallel-load
mode (S0 and S1 are high), data is loaded into the
associated flip-flop and appears at the output after
the positive transition of the CLOCK input. During
loading, serial data flow is inhibited. Shift-right and
shift-left are accomplished synchronously on the
positive clock edge with serial data entered at the
SHIFT RIGHT and SHIFT LEFT serial inputs, re-
spectively. Clearing the register is accomplished by
setting both mode controls low and clocking the reg-
ister. When the output enable input is low, all outputs
assume the high impedance state. The
HCC/HCF40194B is a universal shift register featur-
ing parallel inputs, parallel outputs SHIFT RIGHT and
SHIFT LEFT serial inputs, and a direct overriding
clear input. In the parallel-load mode (S0 and S1 are
high), data is loaded into the associated flip-flop and
June 1989
PIN CONNECTIONS
40104B
40194B
1/12

1 page




HCF40194B pdf
HCC/HCF40104B/40194B
STATIC ELECTRICAL CHARACTERISTICS (over recommended operating conditions)
Symbol Parameter
Test Conditions
VI VO |IO | VD D
(V) (V) (µA) (V)
T Lo w*
Min. Max.
Value
25°C
Min. Typ. Max.
T High*
Min. Max.
Unit
IL Quiescent
0/ 5
Current HCC 0/10
Types 0/15
5 5 0.04 5 150
10 10 0.04 10 300
15 20 0.04 20 600
0/20
20 100 0.08 100 3000 µA
0/ 5
HCF
Types
0/10
0/15
5 20 0.04 20 150
10 40 0.04 40 300
15 80 0.04 80 600
VOH Output High
Voltage
0/ 5
0/10
< 1 5 4.95
< 1 10 9.95
4.95
9.95
4.95
9.95 V
0/15
< 1 15 14.95
14.95
14.95
VOL Output Low
Voltage
5/0
10/0
<1 5
< 1 10
0.05
0.05
0.05 0.05
0.05 0.05 V
15/0
< 1 15
0.05
0.05 0.05
VIH Input High
Voltage
0.5/4.5 < 1 5 3.5
1/9 < 1 10 7
3.5
7
3.5
7V
1.5/13.5 < 1 15 11
11
11
VIL Input Low
Voltage
4.5/0.5 < 1 5
9/1 < 1 10
1.5
3
1.5 1.5
3 3V
13.5/1.5 < 1 15
4
44
I OH Output
0/ 5 2.5
Drive
Current
HCC 0/ 5
Types 0/10
4.6
9.5
5 –2
5 – 0.64
10 – 1.6
– 1.6 – 3.2
– 0.51 – 1
– 1.3 – 2.6
– 1.15
– 0.36
– 0.9
0/15 13.5
0/ 5 2.5
15 – 4.2
5 – 1.53
– 3.4 – 6.8
– 1.36 – 3.2
– 2.4
– 1.1
mA
HCF 0/ 5
Types 0/10
4.6
9.5
5 – 0.52
10 – 1.3
– 0.44 – 1
– 1.1 – 2.6
– 0.36
– 0.9
0/15 13.5
15 – 3.6
– 3.0 – 6.8
– 2.4
I OL Output
0/ 5 0.4
Sink
Current
HCC
Types
0/10
0.5
0/15 1.5
0/ 5
HCF
Types 0/10
0/15
0.4
0.5
1.5
5 0.64
10 1.6
15 4.2
5 0.52
10 1.3
15 3.6
0.51
1.3
3.4
0.44
1.1
3.0
1
2.6
6.8
1
2.6
6.8
0.36
0.9
2.4
0.36
0.9
2.4
mA
I IH, IIL
Input
Leakage
Current
HCC 0/18
Types
HCF 0/15
Types
Any Input
18
15
± 0.1
± 0.3
±10– 5 ± 0.1
±10– 5 ± 0.3
±1
µA
±1
CI Input Capacitance
Any Input
5 7.5
pF
* TLOW= – 55°C for HCC device : – 40°C for HCF device.
* THIGH= + 125°C for HCC device : + 85°C for HCF device.
The noise Margin for both ”1” and ”0” level is : 1V min. with VDD = 5V, 2V min. with VDD = 10V, 2.5 min. with VDD = 15V
5/12

5 Page





HCF40194B arduino
DIM.
A
B
D
d1
d2
E
e
e3
F
G
M
M1
HCC/HCF40104B/40194B
MIN.
9.78
8.89
4.2
7.37
PLCC20 MECHANICAL DATA
mm
TYP.
2.54
0.56
1.27
5.08
0.38
1.27
1.14
MAX.
10.03
9.04
4.57
MIN.
0.385
0.350
0.165
8.38 0.290
0.101
inch
TYP.
0.100
0.022
0.050
0.200
0.015
0.050
0.045
MAX.
0.395
0.356
0.180
0.330
0.004
P027A
11/12

11 Page







PáginasTotal 12 Páginas
PDF Descargar[ Datasheet HCF40194B.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
HCF40194B4-BIT BIDIRECTIONAL UNIVERSAL SHIFT REGISTERSTMicroelectronics
STMicroelectronics

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar