Wiring diagram
PCB front view
123
456
Warning
Do not use a
switching power
supply because
of the
interference
radiation that
may disturb the
reading of the
badges
Strike
V1
Input voltage
230V~ 12V ~ or =
789
12 3 0 #
ST1
RL1 RL2
R C T R C T S S B M E 1 2 3 4 5 6 12 V 12 V
PB1
M
A
G
N V2
E
T
PB2
B Push button 1
E Push button 2
M Common PB1 PB2
R N/C contact
C Common
T N/O contact
V1 Varistor RL1
V2 Varistor RL2
ST1 Reset jumper
S, S Trigger output
RL1 Door 1 relay output
RL2 Door 2 relay output
12 Input voltage
V Input voltage
1 Data
2 Buzzer
3 Green LED
4 Common
5 Red LED
Auxiliary reader
(terminal connections)
See wiring diagram of
auxiliary readers
12 V 1 4 5 3 2
This device comes with a varistor.
The varistor must be connected to the strike terminal
(electromagnet…) operated by the device.
If this product works with many strikes, each of them should
have a varistor.
The varistor controls the overload produced by the strike coil –
self-effect.
If you are using a « Shear Lock » electromagnetic lock, it is recommended to use a
separate power supply than the one connected to the DG502 !

1 Page





DG502 pdf, ピン配列
Edition 17/02/00
Setting a new master code
1. Enter the master code twice (for the first use the master code default value is 12345).
2 beeps and the orange LED lights on confirming that you are in programming mode.
2. Enter *3 then the 5-digit new master code. The LED goes off for 1 second and an
audible beep indicates that the new master code is memorised.
3. Press # to exit from the programming mode. 2 beeps confirm that you are back to the
reading mode.
4 beeps indicate a data computing error.
Setting Time delays
Enter the master code twice (for the first use the master code default value is 12345).
2 beeps and the orange LED lights on confirm the entry in programming mode.
Programming modes
and operating
Door relay 1
Door relay 2
Enter 0, then 00 for a local programming mode (proximity)
The main reader is the only one to operate the programming.
Enter 0, then 01 for a remote programming mode (magstripe)
The auxiliary reader 1is the only one to operate programming
In normal mode (reading mode), when set in local programming
mode all readers can be used, in a remote programming mode
only the auxiliary readers operate.
LED l goes off for 1 second and an audible beep indicates
the validation of the programming.
Enter 1, then the time delay in seconds :
01 equals 1 second up to 99 for 99 seconds.
00 corresponds to latched output.
The LED goes off for 1 second and an audible beep indicates
the validation of the time delay.
Enter 2, then the time delay in seconds :
01 equal 1 second up to 99 for 99 seconds.
00 corresponds to latched output.
The LED goes off for 1 second and an audible beep indicates
the validation of the time delay.
Press # to exit from programming mode. 2 beeps confirm that you returned to reading
mode.
4 beeps indicate a data computing error.
Setting new proximity badges
1. Enter the master code twice (for the first use the master code default value is 12345).
2 beeps and the orange LED lights on to confirm that you have entered into the
programming mode.
2. Enter the badge position number to be programmed (000 to 499). The LED
goes off for 1 second and audible beeps are activated.
3. If the green LED is on, present the badge in front of the main reader. The
LED goes off for 1 second and an audible beep is emitted. The orange LED
lights on to confirm that badge has been memorised.
4. If the red LED is on (this badge position number is already taken), cancel
the old badge before programming a new one, or go to a new position.
5. To exit from the programming mode at any time press #. 2 beeps confirm
that you have returned to the reading mode.
3


3Pages


DG502 電子部品, 半導体
Edition 17/02/00
Wiring diagram of auxiliary reader 1
DG502
R C T R C T S S B M E 1 2 3 4 5 6 12 V 12 V
Distance :
min 60 cm,
max 50 m
Rear view of the reader
12 V 1 4 5 3 2
Wiring between DG502—Reader 1
DG502
Reader 1
12 Input voltage
12
V Input voltage
V
1 Data
1
2 Buzzer
2
3 Green LED
3
4 Common
4
5 Red LED
5
6

6 Page



ページ 合計 : 10 ページ
 
PDF
ダウンロード
[ DG502 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
DG502

STAND-ALONE PROXIMITY SYSTEM / 500 PROXIMITY BADGES 2 DOORS

CDVI
CDVI
DG502AP

2-DOOR CONTROLLER

CDVI
CDVI
DG502UA

2-DOOR CONTROLLER

CDVI
CDVI
DG5043

Monolithic General Purpose CMOS Analog Switch

Vishay Intertechnology
Vishay Intertechnology


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap