CAUTION
BEFORE SERVICING THE CHASSIS,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.

1 Page





32LH70YR-TA pdf, ピン配列
SAFETY PRECAUTIONS
IMPORTANT SAFETY NOTICE
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in the
Schematic Diagram and Exploded View.
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent
Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.
General Guidance
An isolation Transformer should always be used during the
servicing of a receiver whose chassis is not isolated from the AC
power line. Use a transformer of adequate power rating as this
protects the technician from accidents resulting in personal injury
from electrical shocks.
It will also protect the receiver and it's components from being
damaged by accidental shorts of the circuitry that may be
inadvertently introduced during the service operation.
If any fuse (or Fusible Resistor) in this TV receiver is blown,
replace it with the specified.
When replacing a high wattage resistor (Oxide Metal Film Resistor,
over 1W), keep the resistor 10mm away from PCB.
Keep wires away from high voltage or high temperature parts.
Before returning the receiver to the customer,
always perform an AC leakage current check on the exposed
metallic parts of the cabinet, such as antennas, terminals, etc., to
be sure the set is safe to operate without damage of electrical
shock.
Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source, connect an
electrical jumper across the two AC plug prongs. Place the AC
switch in the on position, connect one lead of ohm-meter to the AC
plug prongs tied together and touch other ohm-meter lead in turn to
each exposed metallic parts such as antenna terminals, phone
jacks, etc.
If the exposed metallic part has a return path to the chassis, the
measured resistance should be between 1MΩ and 5.2MΩ.
When the exposed metal has no return path to the chassis the
reading must be infinite.
An other abnormality exists that must be corrected before the
receiver is returned to the customer.
Leakage Current Hot Check (See below Figure)
Plug the AC cord directly into the AC outlet.
Do not use a line Isolation Transformer during this check.
Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
between a known good earth ground (Water Pipe, Conduit, etc.)
and the exposed metallic parts.
Measure the AC voltage across the resistor using AC voltmeter
with 1000 ohms/volt or more sensitivity.
Reverse plug the AC cord into the AC outlet and repeat AC voltage
measurements for each exposed metallic part. Any voltage
measured must not exceed 0.75 volt RMS which is corresponds to
0.5mA.
In case any measurement is out of the limits specified, there is
possibility of shock hazard and the set must be checked and
repaired before it is returned to the customer.
Leakage Current Hot Check circuit
AC Volt-meter
To Instrument's
exposed
METALLIC PARTS
0.15uF
Good Earth Ground
such as WATER PIPE,
CONDUIT etc.
1.5 Kohm/10W
When 25A is impressed between Earth and 2nd Ground
for 1 second, Resistance must be less than 0.1
*Base on Adjustment standard
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
-3-
LGE Internal Use Only


3Pages


32LH70YR-TA 電子部品, 半導体
SPECIFICATION
NOTE : Specifications and others are subject to change without notice for improvement.
1. Application range
This spec sheet is applied to LCD TV used LP91D chassis.
2. Specification
Each part is tested as below without special appointment.
3. Test method
1) Performance: LGE TV test method followed
2) Demanded other specification
- Safety: CE, IEC specification
- EMC : CE, IEC
1) Temperature : 25±5ºC (77±9ºF), CST : 40±5ºC
2) Relative Humidity : 65±10%
3) Power Voltage : Standard input voltage(100~240V@50/60Hz)
* Standard Voltage of each products is marked by models.
4) Specification and performance of each parts are followed
each drawing and specification by part number in
accordance with BOM.
5) The receiver must be operated for about 5 minutes prior to
the adjustment.
4. Electrical specification
4.1. General Specification
No Item
Specification
1 Screen Size
32” wide Color Display Module
2 Aspect Ratio
16:9
3 LCD Module
32” TFT WUXGA LCD
4 Operating Environment Temp.: 0 ~ 40 deg
Humidity : 0 ~ 80 %
5 Storage Environment Temp.: -20 ~ 60 deg
Humidity : 0~ 85 %
6 Input Voltage
AC100-240V~, 50/60Hz
≤ 180 W
32” FHD, 100Hz
7 LDC Module
FHD
760 x 450 x 48
(Maker : LGD)
0.36375 x 0.36375
Measurement
Remark
Resolution : 1920*1080
FHD
Coating
3H
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
-6-
LGE Internal Use Only

6 Page



ページ 合計 : 29 ページ
 
PDF
ダウンロード
[ 32LH70YR-TA データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
32LH70YR-TA

LCD TV SERVICE MANUAL

LG
LG


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap