DataSheet.es    


PDF RTD2555LRH Data sheet ( Hoja de datos )

Número de pieza RTD2555LRH
Descripción Flat Panel Display Controller
Fabricantes Realtek 
Logotipo Realtek Logotipo



Hay una vista previa y un enlace de descarga de RTD2555LRH (archivo pdf) en la parte inferior de esta página.


Total 30 Páginas

No Preview Available ! RTD2555LRH Hoja de datos, Descripción, Manual

REALTEK
LRH Series-GR
RTD 2525/2545/2555 LRH
Flat Panel Display Controller
Preliminary
Revision
Version 1.00
Last updated: 2008/7/16

1 page




RTD2555LRH pdf
REALTEK
LRH Series-GR
V1/REXT 1
LANE1P/V2/RX1P 2
LANE1N/V3/RX1N 3
LANE2P/V4/RX0P 4
LANE2N/V5/RX0N 5
LANE3P/V6/RXCP 6
LANE3N/V7/RXCN 7
AVS 8
AHS 9
ADC_GND 10
B- 11
B+ 12
RTD2545LR
36 TXO1-
35 TXO1+
34 TXO2-
33 TXO2+
32 TXOC-
31 TXOC+
30 TXO3-
29 TXO3+
28 TXE0-
27 TXE0+
26 TXE1-
25 TXE1+
Pin Out Diagram of RTD 2525/2545/2555 LRH
5

5 Page





RTD2555LRH arduino
REALTEK
Buffer_Ovf1
1
R
Buffer_Udf1
0
R
Write to clear status.
Register:: STATUS1
Name
Bit
Buffer_Ovf2
7
R/W
R
Buffer_Udf2
6
R
DENA_Stop
5
R
DENA_Start
4
R
DVS_Start
3R
IENA_Stop 2 R
IENA_Start 1 R
IVS_Start
0
Write to clear status.
R
LRH Series-GR
is set to “1”.
0 Input Overflow Status (Frame Sync
Mode) *1
If an overflow in the input data capture
buffer occurs, this bit is set to “1”.
0 Line Buffer Underflow Status (Frame
Sync Mode)
If an underflow in the line-buffer
occurs, this bit is set to “1”.
Default
0
0
0
0
0
0
0
0
Description
0x03
Config.
Line Buffer Overflow Status
1: Line Buffer overflow has occurred
since the last status cleared
Line Buffer Underflow Status
1: Line Buffer underflow has occurred
since the last status cleared
DENA Stop Event Status
1: If the DENA stop event occurred
since the last status cleared
DENA Start Event Status
1: If the DENA start event occurred
since the last status cleared as an
interrupt source
DVS Start Event Status
1: If the DVS start event occurred
since the last status cleared
IENA Stop Event Status
1: If the IENA stop event occurred
since the last status cleared
IENA Start Event Status
1: If the IENA start event occurred
since the last status cleared
IVS Start Event Status
1: If the IVS start event occurred since
the last status cleared
*1Only first event of input overflow/underflow is recorded if both of them occurs.
11

11 Page







PáginasTotal 30 Páginas
PDF Descargar[ Datasheet RTD2555LRH.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
RTD2555LRHFlat Panel Display ControllerRealtek
Realtek

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar