Descripción Gas probe
Fabricantes BEINAT 
Logotipo BEINAT Logotipo



Hay una vista previa y un enlace de descarga de HCF100 (archivo pdf) en la parte inferior de esta página.


Total 8 Páginas

No Preview Available ! HCF100 Hoja de datos, Descripción, Manual

Gas probe
Belongin to
Firmware.
Versione V 1.0
HCF100
Refrigerant FREON 410A, R134A, 407C
The new HCF100 is born from the elegance and prestige that has always distinguished
BEINAT S.r.l. and from the home fitness concept.
The probe is a Catalytic gas detection unit with IP55 protection that, together with one of
BEINAT’s industrial type Control Units, detects the presence of TOXIC GASES such as:
Refrigerant FREON.
The probe is managed by a microprocessor which not only supplies an alarm signal to the
control unit connected to it, but also allows execution of a self-diagnosis and therefore an
AUTOMATIC CALIBRATION, in order to always have the maximum detection accuracy.
The self-calibration means the probe adapts in harsh and variable temperature environments,
avoiding false alarms due to anomalous events.
The probe has a 0 ÷ 999 ppm linear output, conforming to the 4 ÷ 20mA standard.
Instrument of testing MS222
Using the MS222 instrument created for the event, and supplied to the technicians, it is
possible to see how many calibration corrections were made, read the gas concentration
detected, check how many times it issued an alarm, check the number of voltage failures,
and see the out of service removal date.
Furthermore, being provided with serial transmission, its plant control and verification
report can be printed, thus certifying your own work.
IFsi rtmawllaartei.on and user guide
VFeirrsmiownaer e3 .1
Version 1.0
CONFORMITY
EMC EN50270
Important Note
Before connecting the unit careful reading of instruction booklet is recommended, and it is kept
in a safe place for future reference.
Furthermore, the correct electrical connections according to the enclosed drawings, complying
with instructions and Regulations in force, is recommended.
Free Datasheet http://www.Datasheet4U.com

1 page




HCF100 pdf
mA – Volt Conversion Diagrams
Current-Voltage Conversion Graph
with 220 Ohm Load Resistance
m A Linear +/-5%
0,88 1,1 2,2 3,3 4,4 V.
Troubleshooting before calling a technician
If the device does not start up.
Check that the 12/24 Vdc power is present, and that positive and negative polarity has not been
inverted.
If the Fault LED lights up.
If the fault signal reaches the control unit connected to the probe.
Check that the cables are connected according to the drawing, and that the wire isolation sheath
has not been pinched.
Check the voltage at the terminals 1-2. It must be higher than 11Vdc and lesser than 25Vdc.
Check the voltage at the terminals 2-3. It must be from a minimum of 0.8 Vdc to a maximum of 1.1
Vdc.
WARNING.
These measurement should be
performed in clean air.
Moreover, this test must be
performed only with the probe
connected to a control unit, or with a
220 Ohm resistance installed
between terminal 2 and terminal 3.
.
Voltmeter
1 1,1 2
03
V.
R
321
Power Supply
12÷24 V.
Linear Output 4-20 mA
If other problems arise, a specialised and/or authorised technician and/or the Distributor of
BEINAT S.r.l. should be contacted directly.
Page 5
Free Datasheet http://www.Datasheet4U.com

5 Page










PáginasTotal 8 Páginas
PDF Descargar[ Datasheet HCF100.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
HCF100SensorDuomo
Duomo
HCF100Gas probeBEINAT
BEINAT

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar