製品の詳細 ( Datasheet PDF )

部品番号 5EFM4SC
部品説明 Power Entry Module
メーカ Tyco
ロゴ Tyco ロゴ 




このページの下部にプレビューと5EFM4SCダウンロード(pdfファイル)リンクがあります。

Total 8 pages

No Preview Available !

5EFM4SC Datasheet, 5EFM4SC PDF,ピン配置, 機能
M Series
CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications
UL Recognized
CSA Certified
VDE Approved
XM/ZM
VM
M Series
The M series power entry modules offer the most choices
of power entry components and filtering options to fit a
specific need. The fully configured M series expands the
options of a manufacturer whose products are marketed
worldwide. One component, fully assembled and tested,
provides the capability of interfacing a multi-voltage power
supply to any common voltage or fusing scheme in the
world, without modification.
•The IEC connector provides an internationally accepted
power entry termination, which can be used with a variety
of line cords.
•The selectable fuseholder allows use of single or dual
European fuses, or a single North American fuse.
•The optional DPST on/off switch breaks both sides of the
line and is labeled with the international I/O markings.
•The optional voltage selector provides a convenient
means to change transformer primary connection,
and it is available in both 2-voltage and 4-voltage
configurations.
•The series is available with four filter circuits to meet a
variety of applications, and convenient connections are
provided on unfiltered models to allow wiring of a
separate RFI filter.
The M series is a family of components offering greater
flexibility and cost-effectiveness in the selection of primary
power components. Wiring to the modules is accom-
plished via .110” terminals for labor savings and
convenience.
FM Models – General purpose RFI filter designed for sus-
ceptibility applications, effectively providing RFI control of
line-to-ground noise. The design is compact and meets
the very low leakage current requirements of VDE portable
equipment as well as (120 Volt) UL544 non-patient medical
equipment.
XM Models – High performance RFI filter designed to bring
most digital equipment (including switching power
supplies) into compliance with FCC Part 15J, Class B
conducted emissions limits.
ZM Models – Premium RFI filter designed to bring most
digital equipment (including switching power supplies) into
compliance with EN55022, Level B (as well as FCC Part
15J, Class B) conducted emissions limits.
Fuse Installation Instructions
Four filter circuits provide a choice of attenuation tailored to
specific categories of susceptibility and emissions needs.
HM Models – This medical filter provides susceptibility
protection without the leakage current associated with
line-to-ground capacitors. Designed to allow equipment
to meet UL544 for patient care and non-patient care
equipment, the HM filter has a maximum leakage current
of 2 µA at 120 VAC 60 Hz. See Appendix C for more
information on medical applications and UL standards.
1. Remove power cord.
2. Pry door open at socket.
3. Lift and swing door into socket.
4. Lift fuse holder out of housing.
5. Install one (1) AG fuse or two (2) metric fuses*.
6. Replace fuse holder into housing.
7. Swing and snap door back in place.
*Install fuses on one side only, do not install both AG and metric fuses at the
same time.
124
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheet-pdf.com/

1 Page





5EFM4SC pdf, ピン配列
CORCOM Product Guide
M Series
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
Specifications
Maximum leakage current,each line-to-ground
HM FM
XM/ZM
@ 120 VAC 60 Hz:
@ 250 VAC 50 Hz:
Hipot rating (one minute):
2µA .25 mA .30 mA
5µA .50 mA .50 mA
line-to-ground:
1500 VAC
line-to-line
1450 VDC
line-to-load (switch off) Unfiltered only 2500 VAC
Operating frequency:
50/60 Hz
Rated voltage (max.):
250 VAC
Operating voltages:
100, 120, 220/ 240 VAC
Switch:
Double-insulated, rated for
100,000 operations at full load
at 70 Amps inrush current.
Fuse (not included):
Reversible fuseholder, accepts
one 1/4" x 1-1/4" fuse
or two 5 x 20 mm fuses
Terminals:
.110 [2.79] terminals
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Rating
HM
5A
FM
05A
XM
3A
ZM
3A
Frequency-MHz
.01 .05 .15 .5 1 5
- - 14 18 19 22
- - 14 21 26 40
2 13 23 40 46 44
15 29 39 46 43 40
10 30
22 17
45 40
44 44
40 40
Line-to-line in 50 ohm circuit
Current
Rating
XM
03A
ZM
3A
Frequency-MHz
.02 .03 .05 .07 .15 .5 1 5 10
- - - 5 34 62 68 60 50
5 13 28 37 55 75 75 62 54
30
40
44
Electrical Schematics – Unfiltered Models
VM (1-Voltage)
Neutral
Note 2
Power On/Off
Note 3
KK
Hot
120V
LL
G Customer
Transformer Primaries
VM (2-Voltage)
Neutral
Power On/Off
Note 3
Note 2
K
120V
Note 1
H
Hot
LJ
Note 1
240V
A
B
B
C
DD
EE
FF
G
120V
A
120V
C
120V
120V
F
Customer Note 4
Transformer Primaries
VM (4-Voltage)
Neutral
Power On/Off
Note 3
Note 2
K
120V
100V
Note 1
H
Hot
LJ
Note 1
230V
240V
A
B
A
20V
100V
CC
DD
EE
120V
FF
G Customer
Transformer Primaries
Note 1:
Note 2:
Note 3:
Note 4:
Jumpers required if no input filter is used.
Provision for dual European style fusing.
On/off switch present only with "S" suffix.
When using a center-tapped transformer, the C-F winding should
be the low voltage (high current) winding and must be capable of
handling the full primary current in the 120V position.
126
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheet-pdf.com/


3Pages


5EFM4SC 電子部品, 半導体
CORCOM Product Guide
M Series
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
Case Styles - Filtered Models (cont'd)
5EHM1 & 5EFM1 (IEC Connector, Selectable
Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
D
B
A
C
E
5EFM1C (IEC Connector, Selectable Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
A
D
C
5EHM4 & 5EFM4 (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder)
USE ONLY WITH
100V
120V
250V FUSES 230V
240V
DISCONNECT POWER
BEFORE REPLACING FUSES
D
B
A
C
E
5EFM4C (IEC Connector, Voltage Selector, Selectable
Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
100V
120V
230V
240V
A
D
C
EE
5EHM1S & 5EFM1S (IEC Connector, DPST On/Off
Switch, Selectable Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
D
B
A
C
E
5EFM1SC (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder)
USE ONLY WITH
250V FUSES
DISCONNECT POWER
BEFORE REPLACING FUSES
A
C
D
E
5EHM4S & 5EFM4S (IEC Connector, DPST On/Off
Switch, Voltage Selector, Selectable Fuseholder)
USE ONLY WITH
100V
120V
250V FUSES 230V
240V
DISCONNECT POWER
BEFORE REPLACING FUSES
D
B
A
C
E
Typical dimensions:
Torque: 7 in. lb max.
Holes: .055 [1.40] Dia. ±.004 [±.10] except solder lug ground tap with wire wrap.
Mounting Holes: .155 [3.94] Dia.
All parts typical.
Note: Mounting holes on tabs are countersunk and take a #6 flathead screw.
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
129
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheet-pdf.com/

6 Page



ページ 合計 : 8 ページ
 
PDF
ダウンロード
[ 5EFM4SC データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
5EFM4S

Power Entry Module

Tyco
Tyco
5EFM4SC

Power Entry Module

Tyco
Tyco


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap