Sec. 1
Sec. 2
Sec. 3
Sec. 4
Sec. 5
Service Information
Block Diagrams
Schematic Diagrams
Circuit Board Diagrams
Exploded Views &
Replacement Parts List
ORDER NO. CBMD0601005
Remote Operation Panel
AW-CB400N/L
© 2006 Matsushita Electric Industrial Co., Ltd. All rights reserved.
Unauthorized copying and distribution is a violation of law.
Free Datasheet http://www.datasheet-pdf.com/
1 Page For AW-CB400L
Specifications
Supply voltage:
DC 12.0 V
Power consumption: 3.8 W
indicates safety information.
Input connectors
DC 12V IN:
GND:
XLR, 4 pins
GND terminal
Output connectors
CONTROL OUT
TO CONTROL PANEL:
CONTROL OUT
TO CAMERA 1 to 5:
D-SUB 29-pin
RJ45, camera control RS-422 level
10Base-T straight cable (UTP category 5), max. 1000 meters
Input/output connectors
INCOM (top panel):
TALLY/INCOM:
XLR, 4 pins
D-SUB 15-pin
TALLY: Contact input (do not apply a voltage in excess of 5V)
INCOM: 4-wire system
Switch functions:
Adjustment functions:
Ambient operating temperature:
Storage temperature:
Ambient operating humidity:
Dimensions (W x H x D):
Weight:
Finish:
DATA SET, menu, camera control selection, DTL, scene file selection, gain selection,
BAR/CAM switching, white balance selection, AWC, ABC, call, lens iris
AUTO/MANU/LOCK switching, option switches (1 to 4)
LCD contrast, INCOM level, lens iris, menu settings, R-GAIN, B-GAIN, pedestal, R-PED,
B-PED
- 10˚C to +45˚C
- 20˚C to +60˚C
30% to 90% (no condensation)
100 x 85 x 266 mm
1.4 kg
Colour resembling Munsell 3.5 paint
Weight and Dimensions indicated above are approximate.
Specifications are subject to change without notice.
Accessories
Pan/tilt control panel (AW-RP400) connecting cable ...... 1
Tally/INCOM connector (D-SUB 15-pin) ......................... 1
Rack-mounting adaptors ................................................. 2
Join-up fixture .................................................................. 1
Mounting screws (M4 x 8 mm) ........................................ 8
Join-up screws (stepped screws) .................................... 2
Joining sticker .................................................................. 2
- -3-
Free Datasheet http://www.datasheet-pdf.com/
3Pages For AW-CB400N
Safety precautions
IMPORTANT SAFETY INSTRUCTIONS
Read these operating instructions carefully before using the unit. Follow the safety instructions on the unit and the
applicable safety instructions listed below. Keep these operating instructions handy for future reference.
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
10) Protect the power cord form being walked on or
pinched particularly at plugs, convenience
receptacles, and the point where they exit from
the apparatus.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in
accordance with the manufacturer's instructions.
8) Do not install near any heat sources such as
radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9) Do not defeat the safety purpose of the polarized
or grounding-type plug. A polarized plug has two
blades with one wider than the other. A grounding-
type plug has two blades and a third grounding
prong. The wide blade or the third prong are
provided for your safety. If the provided plug does
not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
11) Only use attachments/accessories specified by
the manufacturer.
12) Use only with the cart, stand, tripod,
bracket, or table specified by the
manufacturer, or sold with the
apparatus. When a cart is used, use
caution when moving the
cart/apparatus combination to avoid
injury from tip-over.
13) Unplug this apparatus during lightning storms or
when unused for long periods of time.
14) Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has
been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.
indicates safety information.
-
-6-
Free Datasheet http://www.datasheet-pdf.com/
6 Page | |||
ページ | 合計 : 30 ページ | ||
|
PDF ダウンロード | [ AW-CB400L データシート.PDF ] |
データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。 |
部品番号 | 部品説明 | メーカ |
AW-CB400L | Remote Operation Panel Manual | Panasonic |
AW-CB400N | Remote Operation Panel Manual | Panasonic |