Número de pieza | IT8721F-DX | |
Descripción | Ibex Peak platform cause S3 resume fail issue | |
Fabricantes | ELITEGROUP COMPUTER SYSTEMS | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de IT8721F-DX (archivo pdf) en la parte inferior de esta página. Total 10 Páginas | ||
No Preview Available ! ELITEGROUP COMPUTER SYSTEMS CO., LTD.
Date: 3/10/2011
Page: 1
SIO IT8721F-BX/DX in
Ibex Peak platform
cause S3 resume fail
issue
Issue Topic:
Technical Issue Survey Form
Prepared by:
RD Department:
FISH
BUI/ODM1
Doc.: ECS Technical Issue Survey Form V.A
Free Datasheet http://www.datasheet4u.com/
1 page ELITEGROUP COMPUTER SYSTEMS CO., LTD.
Date: 3/10/2011
Page: 5
Root cause : Power sequence between PCH core 1.05V and PWROK resume from S3 to
S0 are failure.
Solution : PWROK output signal changed from pin 32 PWRGD1_30ms to pin 78
PWRGD3_150ms to meet the correctly power sequence of PCH core 1.05V stable to
PWROK active specification , and configure SIO PWRGD3_150ms time t5 to 135ms from
register address 2A , Bit 0=1, refer to below picture:
1)SIO connect to pin78 :
2)SIO register set address 2A,Bit 0=1 :
3)Correctly waveform with implementation of solution , PCH core 1.05V stable 106 ms to PWROK active :
Doc.: ECS Technical Issue Survey Form V.A
Free Datasheet http://www.datasheet4u.com/
5 Page |
Páginas | Total 10 Páginas | |
PDF Descargar | [ Datasheet IT8721F-DX.PDF ] |
Número de pieza | Descripción | Fabricantes |
IT8721F-DX | Ibex Peak platform cause S3 resume fail issue | ELITEGROUP COMPUTER SYSTEMS |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |