Instruction Manual
R-DPA96A
http://www.DataSheet4U.com/
R-DPA96 A/AN
DIGITAL POWER ANALYSER
BRIDEX Singapore Pte., Ltd
1 Page LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED_________________86
RESET TO ZERO: ENERGY METERS AND MAX. VALUES _________________95
SAVED COMMAND ___________________________________________________96
PULSE METERS VALUES ______________________________________________96
DATE AND HOUR SETTINGS___________________________________________97
LAST 10 ALARMS EVENT LOG _________________________________________97
LAST 10 VOLTAGE DIPS EVENT LOG / SAG ____________________________111
LAST 10 VOLTAGE SURGE EVENT LOG / SWELL _______________________116
MINIMUM AND MAXIMUM INSTANTANEOUS VALUES ___________________121
LAST 10 VOLTAGE CUT-OFFS EVENT LOG / SAG _______________________125
MEAN POWER EVENT LOG___________________________________________127
MEAN VOLTAGE EVENT LOG _________________________________________127
MEAN FREQUENCY EVENT LOG ______________________________________127
TECHNICAL CHARACTERISTICS ___________________________________________128
GLOSSARY OF ABBREVIATIONS ___________________________________________128
PRELIMINARY OPERATIONS _______________________________________________ 131
PRESENTATION __________________________________________________________ 131
INSTALLATION ___________________________________________________________ 132
PROGRAMMING__________________________________________________________ 133
TECHNICAL CHARACTERISTICS ___________________________________________ 138
GLOSSARY OF ABBREVIATIONS____________________________________________138
http://www.DataSheet4U.com/
PRELIMINARY OPERATIONS _______________________________________________ 141
PRESENTATION __________________________________________________________ 141
INSTALLATION ___________________________________________________________ 142
PROGRAMMING__________________________________________________________ 144
OPERATION ______________________________________________________________ 150
TECHNICAL CHARACTERISTICS ___________________________________________ 151
GLOSSARY OF ABBREVIATIONS____________________________________________151
PLEASE CONSULT US
PRELIMINARY OPERATIONS _______________________________________________ 153
PRESENTATION __________________________________________________________ 154
INSTALLATION ___________________________________________________________ 155
PROGRAMMING__________________________________________________________ 156
OPERATION ______________________________________________________________ 168
TECHNICAL CHARACTERISTICS ___________________________________________ 169
GLOSSARY OF ABBREVIATIONS____________________________________________168
RUDOLF - Ref. : 876 583 A
3
3Pages R-DPA96 A/AN
INSTALLATION
CONNECTION
OPTIONAL MODULES
The maximum coupling torque for each screw is 0.4
Nm.
Each CT’s secondary winding must be short-circuited
when disconnecting the R-DPA96 A/AN is can be
done automatically using one of Socomec’s cata-
logue products: the PTI. Please contact us for further
information.
The R-DPA96 A/AN can be tted with optional
modules:
- JBUS/MODBUS communication;
ref: R-MODULE 3:
RS485 JBUS/MODBUS serial port in RTU mode with
a speed from 2400 to 38400 baud. (User manual ref:
CDR 27 028)
1 Aux.:
2 Fus.:
110 … 400 V AC
120 … 350 V DC
12 … 48 V DC
0.5 A gG / BS 88 2A gG / 0.5 A class CC
- PROFIBUS-DP Communication;
ref: R-MODULE 3+6:
RS485 PROFIBUS-DP serial port with a speed from
9,600 baud to 1.5 Mbaud. (User manual ref: CDR 18
021)
- Pulse outputs; ref: R-MODULE 1:
2 pulse outputs connected to the metering of energy
in kWh, kvarh and KVAh (User manual ref: 876 584)
S1 S2 S1 S2 S1 S2
I1 I2 I3
- Harmonic and pulse outputs; ref: R-MODULE 2:
2 pulse outputs connected to the metering of energy
in kWh, kvarh and KVAh. Analysis of the harmonic
spectrum in current and voltage in rows and in
phases up to row 25 (User manual ref: 876 585
- Analogue outputs; ref: R-MODULE 4:
2 analogue outputs 4/20 mA or 0/20 mA con gurable
for current, voltage, power and power factor. 2
modules can be installed, a maximum of 4 outputs
(User manual ref: 876 586)
R-DPA96 A
S1 S2
V1 V2 V3 VN
2
1
- Inputs/Outputs; ref: R-MODULE 5:
http://www.DataSheet4U.com/
2 outputs allocated for alarms, for voltage, current,
power, power factor and THD, or remote control.
2 inputs for the metering of pulses or controlling posi-
tion (User manual ref: 876 587).
- Storage capability; ref: R-MODULE 7:
Storage capability for storing mean active and reacti-
ve power, minimum and maximum instantaneous
values, the last 10 alarms, troughs/overvoltages and
power cuts according to EN50160 (User manual ref:
876 588).
S1 S2 S1 S2 S1 S2
I1 I2 I3
In
R-DPA96 AN
V1 V2 V3 VN
2
1
6 RUDOLF - Ref. : 876 583 A