DataSheet.es    


PDF HLG-100 Data sheet ( Hoja de datos )

Número de pieza HLG-100
Descripción 100W Single Output Switching Power Supply
Fabricantes Mean Well 
Logotipo Mean Well Logotipo



Hay una vista previa y un enlace de descarga de HLG-100 (archivo pdf) en la parte inferior de esta página.


Total 6 Páginas

No Preview Available ! HLG-100 Hoja de datos, Descripción, Manual

100W Single Output Switching Power Supply
HLG-100 series
Features :
Universal AC input / Full range
Built-in active PFC function
High efficiency up to 93.5%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.9)
F 110 M M SELV IP65 IP67
HLG-100-20 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-100-20 HLG-100-24 HLG-100-30 HLG-100-36 HLG-100-42 HLG-100-48 HLG-100-54
DC VOLTAGE
20V
RATED CURRENT
4.8A
RATED POWER
96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE Note.5 17 ~ 22V
24V
4A
96W
150mVp-p
22 ~ 27V
30V
3.2A
96W
200mVp-p
27 ~ 33V
36V
2.65A
95.4W
200mVp-p
33 ~ 40V
42V
2.28A
95.76W
200mVp-p
38 ~ 46V
48V
2A
96W
200mVp-p
43 ~ 53V
54V
1.77A
95.58W
200mVp-p
49 ~ 58V
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer or through output cable
3 ~ 4.8A
2.5 ~ 4A
2 ~ 3.2A
1.65 ~ 2.65A
VOLTAGE TOLERANCE Note.3 1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
0.5%
0.5%
0.5%
0.5%
1.4 ~ 2.28A
1.0%
0.5%
0.5%
1.25 ~ 2A
1.0%
0.5%
0.5%
1.1 ~ 1.77A
1.0%
0.5%
0.5%
SETUP, RISE TIME Note.7 2500ms, 50ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load 230VAC / 115VAC
HOLD UP TIME (Typ.)
16ms at full load 230VAC /115VAC
www.DataSheet.net/
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC (Please refer to "Power Factor Characteristic" curve)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
93.5%
93.5%
93.5%
1.2A / 115VAC 0.55A / 230VAC
COLD START 75A/230VAC
93.5%
93.5%
93.5%
93.5%
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
95 ~ 106%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
23 ~ 27V
28 ~ 34V
34 ~ 38V
41 ~ 46V
47 ~ 53V
54 ~ 60V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
59 ~ 65V
OVER TEMPERATURE
100 10 (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.6 UL8750, EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
192.2Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
220*68*38.8mm (L*W*H)
PACKING
1.12Kg; 12pcs/14.4Kg/0.74CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Type A only.
6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Refer to warranty statement.
File Name:HLG-100-SPEC 2011-07-28
Datasheet pdf - http://www.DataSheet4U.co.kr/

1 page




HLG-100 pdf
100W Single Output Switching Power Supply
DIMMING OPERATION
HLG-100 series
FG (Green/Yellow)
AC/L(Brown)
AC/N(Blue)
HLG-100
DIM+(Blue)
DIM-(White)
-V(Black)
+V(Red)
Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or
1 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-.
Please DO NOT connect "DIM-" to "-V".
Reference resistance value for output current adjustment (Typical)
Resistance value
10K 20K 30K 40K 50K 60K 70K 80K 90K 100K
OPEN
Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 102%~108%
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN
Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 102%~108%
10V PWM signal for output current adjustment (Typical): Frequency range :100HZ ~ 3KHz
Duty value
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN
Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 102%~108%
Using the built-in dimming function on B-type model can't turn the lighting fixture totally dark. Please refer to the connection method below to
achieve 0% brightness of the lighting fixture connecting to the LED power supply unit.
Dimming connection diagram for turning the lighting fixture ON/OFF :
www.DataSheet.net/
N FG L
Relay
Switch
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Green/
Yellow
Brown
Blue
AC/L
AC/N
HLG-100
B Type
DIM+
DIM-
V(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:HLG-100-SPEC 2011-07-28
Datasheet pdf - http://www.DataSheet4U.co.kr/

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet HLG-100.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
HLG-100100W Single Output Switching Power SupplyMean Well
Mean Well

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar