DESCRIPTION
Compact, rugged, lightweight, fixed frequency pulse
magnetron, electrically the same as M5187.
GENERAL DATA
Electrical
Operating frequency . . . . . 9410 + 30
MHz
Typical peak output power . . . . . . 25
kW
Cathode . . . . . . . . . . . . indirectly heated
Heater voltage (see note 1) . . . . . . . 6.3
V
Heater current at 6.3 V (see note 2) . . . . 0.5
A
Cathode pre-heating time (minimum)
(see note 3) . . . . . . . . . . 60
s
Input capacitance . . . . . . . . . . 9.0 pF max
Temperature coefficient of frequency . . . . see note 4
Mechanical
Output . . . . . . . . . . . . no. 16 waveguide
(22.86 x 10.16 mm internal)
Overall dimensions . . . . . . . . . . . see outline
Net weight . . . . . . . . . . . . 0.7 kg approx
Mounting position . . . . . . . . . . . . . any
Magnet . . . . . . . . . . . . . . . integral
A minimum clearance of 25 mm must be maintained between
the magnetron and any magnetic materials.
Coupler . . . . . . . . . . . . . IEC UBR100
Cooling . . . . . . . . . . . . . . . natural
MAXIMUM AND MINIMUM RATINGS
(Absolute values)
These ratings cannot necessarily be used simultaneously, and
no individual rating should be exceeded.
Min Max
Heater voltage (see note 1) . . . . . 5.7
Heater starting current (peak) . . . . –
Anode voltage (peak) . . . . . . . –
Anode current (peak) . . . . . . . 5.0
Input power (mean) (see note 5) . . . –
Pulse duration . . . . . . . . . –
Rate of rise of voltage pulse
(see notes 6 and 7) . . . . . . . –
VSWR at the output coupler . . . . –
Anode temperature . . . . . . . –
6.9
3.0
8.6
10
100
2.0
V
A
kV
A
W
ms
150 kV/ms
1.5:1
120 8C
TYPICAL OPERATION
Operating Conditions
Heater voltage (for operation) . . . . . . 6.3
Anode current (peak) . . . . . . . . . 8.0
Pulse duration . . . . . . . . . . . 0.8
Pulse repetition rate . . . . . . . . 900
Rate of rise of voltage pulse . . . . . . 80
Typical Performance
Anode voltage (peak) . . . . . . . . . 8.4
Output power (peak) . . . . . . . . 25
Output power (mean) . . . . . . . . 18
V
A
ms
pps
kV/ms
kV
kW
W
E2V Technologies Limited, Waterhouse Lane, Chelmsford, Essex CM1 2QU England Telephone: +44 (0)1245 493493 Facsimile: +44 (0)1245 492492
e-mail: [email protected] Internet: www.e2vtechnologies.com Holding Company: E2V Holdings Limited
E2V Technologies Inc. 4 Westchester Plaza, PO Box 1482, Elmsford, NY10523-1482 USA Telephone: (914) 592-6050 Facsimile: (914) 592-5148
# E2V Technologies Limited 2002
A1A-MG5424 Issue 4, December 2002
527/5729
Datasheet pdf - http://www.DataSheet4U.net/

1 Page





MG5424 pdf, ピン配列
www.DataSheet.co.kr
PERFORMANCE CHART
10
9
8
7
MAXIMUM
MINIMUM
7102
TYPICAL
6
5
4
3
2
1
0
PEAK CURRENT
RATING LIMITS
35
30
25 TYPICAL
20
15 MINIMUM
10
5
0
0 1 2 3 4 5 6 7 8 9 10 11 12
PEAK ANODE CURRENT (A)
HEALTH AND SAFETY HAZARDS
E2V Technologies magnetrons are safe to handle and operate,
provided that the relevant precautions stated herein are
observed. E2V Technologies does not accept responsibility for
damage or injury resulting from the use of electronic devices it
produces. Equipment manufacturers and users must ensure
that adequate precautions are taken. Appropriate warning
labels and notices must be provided on equipments
incorporating E2V Technologies devices and in operating
manuals.
High Voltage
Equipment must be designed so that personnel cannot come
into contact with high voltage circuits. All high voltage circuits
and terminals must be enclosed and fail-safe interlock switches
must be fitted to disconnect the primary power supply and
discharge all high voltage capacitors and other stored charges
before allowing access. Interlock switches must not be
bypassed to allow operation with access doors open.
RF Radiation
Personnel must not be exposed to excessive RF radiation. All
RF connectors must be correctly fitted before operation so that
no leakage of RF energy can occur and the RF output must be
coupled efficiently to the load. It is particularly dangerous to
look into open waveguide or coaxial feeders while the device is
energised. Screening of the cathode sidearm of high power
magnetrons may be necessary.
X-Ray Radiation
High voltage magnetrons emit a significant intensity of X-rays
not only from the cathode sidearm but also from the output
waveguide. These rays can constitute a health hazard unless
adequate shielding for X-ray radiation is provided. This is a
characteristic of all magnetrons and the X-rays emitted
correspond to a voltage much higher than that of the anode.
# E2V Technologies
MG5424, page 3
Datasheet pdf - http://www.DataSheet4U.net/


3Pages





ページ 合計 : 4 ページ
 
PDF
ダウンロード
[ MG5424 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
MG5424

X-Band Magnetron

E2V Technologies
E2V Technologies


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap