DataSheet.es    


PDF DF-G1 Data sheet ( Hoja de datos )

Número de pieza DF-G1
Descripción Expert Dual Display Fiber Amplifier Manual
Fabricantes Banner Engineering 
Logotipo Banner Engineering Logotipo



Hay una vista previa y un enlace de descarga de DF-G1 (archivo pdf) en la parte inferior de esta página.


Total 27 Páginas

No Preview Available ! DF-G1 Hoja de datos, Descripción, Manual

www.DataSheet.co.kr
DF-G1 - Expert Dual Display Fiber Amplifier Manual
Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
Features
• Easy to read dual digital displays show both signal level and threshold simultaneously
• Lever action fiber clamp provides stable, reliable, and trouble-free fiber clamping
• Simple user interface ensures easy sensor set-up and programming via displays and
switches/buttons, or remote input teach wire
Expert TEACH and SET methods ensure optimal gain and threshold for all applica-
tions, especially low contrast applications
• User has full control over all operating parameters: threshold, Light Operate or Dark
Operate, output timing functions, gain level, and response speed
• Thermally stable electronics minimize warm-up drift and the effect of side-by-side
mounting of multiple fiber amplifiers
• ECO (economy) display mode reduces amplifier power consumption by 25%
• Cross talk avoidance algorithm allows two sensors to operate in close proximity for
many applications
• Response speeds of: 200 µs (High Speed), 500 µs (Standard), 2 ms (Long Range),
and 5 ms (Extra Long Range) allow operator to optimize for fast or long distance ap-
plications
• Sleek 10 mm wide housing mounts to 35 mm DIN standard rail
• Visible red LED sensing beam
Models
Model
DF-G1-NS-2M
DF-G1-PS-2M
DF-G1-NS-Q3
DF-G1-PS-Q3
DF-G1-NS-Q7
DF-G1-PS-Q7
Outputs
Single NPN
Single PNP
Single NPN
Single PNP
Single NPN
Single PNP
Connector*
2 m (6.5') cable, 4-wire
150 mm (6") PVC pigtail, M8 Pico QD connector, 4-
pin
Integral M8 Pico QD connector, 4-pin
* Connection options: A model with a QD connector requires a mating cordset (see Quick-Disconnect Cordsets on page 26).
For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G1-NS-9M).
For M12 Euro QD pigtail change the suffix 2M to Q5 in the 2 m model number (example, DF-G1-NS-Q5).
WARNING: Not To Be Used for Personnel Protection
Never use this product as a sensing device for personnel protection. Doing so could lead to seri-
ous injury or death. This product does NOT include the self-checking redundant circuitry necessary to
allow its use in personnel safety applications. A sensor failure or malfunction can cause either an ener-
gized or de-energized sensor output condition.
P/N 161999 Rev. A
1/12/2012
0 161999 7
Datasheet pdf - http://www.DataSheet4U.net/

1 page




DF-G1 pdf
www.DataSheet.co.kr
DF-G1 - Expert Dual Display Fiber Amplifier Manual
P/N 161999 Rev. A
Figure 3.
www.bannerengineering.com - tel: 763-544-3164
5
Datasheet pdf - http://www.DataSheet4U.net/

5 Page





DF-G1 arduino
www.DataSheet.co.kr
DF-G1 - Expert Dual Display Fiber Amplifier Manual
Window SET
• Sets window thresholds that extend a programmable % offset above and below the presented condition
• All other conditions (lighter or darker) cause the output to change state
• Sensing window center can be adjusted using “+” and “-” rocker button (Manual Adjust)
• Recommended for applications where a product may not always appear in the same place, or when other signals may appear
• See Program Mode on page 3 for programming the Offset Percent setting (to increase/decrease the window size)
A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and below the
presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside the window, and the
Output OFF conditions outside the window (see Figure below).
Sensing window
center adjusted by
Manual Adjust
Sensor positions
window thresholds
a programmable %
offset from the
presented condition
Output OFF
Output ON
Output OFF
Darkest
(no signal)
Condition
Presented
Most Light
(saturated
signal)
Figure 7. Window SET (Light Operate shown)
Output ON and OFF conditions can be reversed using the LO/DO switch (see LO/DO Switch in Top Panel Interface on page 2).
Window SET and Manual Adjust
• Moves sensing window center value up or down to make adjustments
• Slide Mode switch to ADJ to enter Adjust mode
• Press “+” to increase; press “-” to decrease
• GREEN display shows the sensing window center value
• 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
• Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
P/N 161999 Rev. A
www.bannerengineering.com - tel: 763-544-3164
11
Datasheet pdf - http://www.DataSheet4U.net/

11 Page







PáginasTotal 27 Páginas
PDF Descargar[ Datasheet DF-G1.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
DF-G1Expert Dual Display Fiber Amplifier ManualBanner Engineering
Banner Engineering
DF-G1Expert Fiber Amplifier Install SheetBanner Engineering
Banner Engineering

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar