DataSheet.jp

GV2P01 の電気的特性と機能

GV2P01のメーカーはSteven Engineeringです、この部品の機能は「Manual Starter and Protector」です。


製品の詳細 ( Datasheet PDF )

部品番号 GV2P01
部品説明 Manual Starter and Protector
メーカ Steven Engineering
ロゴ Steven Engineering ロゴ 




このページの下部にプレビューとGV2P01ダウンロード(pdfファイル)リンクがあります。

Total 6 pages

No Preview Available !

GV2P01 Datasheet, GV2P01 PDF,ピン配置, 機能
www.schneider-electric.us
GV2ME
GV2P21 with
GV2GH7 installed
Starters
TeSys® GV2 and GV3 Manual Starter and Protector
Refewr wtowC.DaatatalSohgee2t542U0.cComT0001
The GV family of products are 3-pole, horsepower rated, UL 508 listed, manual starters. They include a manual
disconnect, class 10 ambient-compensated thermal overload relay, and an instantaneous magnetic trip mechanism in
one compact unit.
Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220
amps. The GV family of products may also be used in group motor installations in accordance with National Electric
Code article 430-53. Group motor installations give you greater panel density for smaller size and require fewer parts
and less wiring necessary for installation when compared to conventional panel designs.
The GV2P and GV3P products also have an additional UL 508 type E rating as a stand alone self-protected manual
combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P
or part number GV3G66 for the GV3P. The GV2P and the GV3P self-protected manual combination starter may also
be combined with specific size contactors from the LC1D product family for a UL 508 Type F combination starter
construction. These products have UL-listed short circuit current rating from 10–100 KA depending on application size
and voltage. See www.us.telemecanique.com for more information.
How to Order
To order the basic motor starter, select the model number (GV2ME••, GV2P••, or GV3P••) with the appropriate thermal
setting from the table below. The thermal trip range and setting should be determined from the motor nameplate full-
load current.
Table 18.124:
Thermal
Setting
(A)
Maximum Horsepower Ratings
1Ø 3Ø
115 V 230 V 200 V 230 V 460 V
hp hp hp hp hp
575 V
hp
Group Motor
Applications
Max. Fuse or
Circuit Breaker
GV2/3M push button
Catalog
Number
$ Price
GV2/3P rotary handle
Catalog
Number
$ Price
0.11–0.16 — — — — — —
1200 A
GV2ME01a
159.
GV2P01
212.
0.16–0.25 — — — — — —
1200 A
GV2ME02a
159.
GV2P02
212.
0.25–0.40 — — — — — —
1200 A
GV2ME03a
159.
GV2P03
212.
0.40–0.63 — — — — — —
1200 A
GV2ME04a
180.
GV2P04
233.
0.63–1 — — — — 0.5 0.5
1200 A
GV2ME05a
180.
GV2P05
233.
1–1.6
— 0.1 —
— 0.75
1
1200 A
GV2ME06a
180.
GV2P06
233.
1.6–2.5
— 0.667 0.5
0.5
1
1.5
2.5–4
1/8 0.333 0.75
1
2
3
1200 A
1200 A
GV2ME07a
GV2ME08a
180.
180.
GV2P07
GV2P08
233.
233.
4–6.3
1/4 0.5 1.5 1.5
3
5
1200 A
GV2ME10a
180.
GV2P10
233.
6–10
0.5 1.5
2
3
5 7.5
1200 A
GV2ME14a
180.
GV2P14
233.
9–14 0.75 2 3 3 10 10
1200 A
GV2ME16a
224.
GV2P16
278.
13–18 1 3 5 5 10 15
1200 A
GV2ME20a
224.
GV2P20
278.
17–23 1.5 3
5 7.5 15 20
1200 A
GV2ME21a
224.
GV2P21
278.
20–25 2 3 5 7.5 15 20
1200 A
GV2ME22a
224.
GV2P22
278.
24–32 2 5 10 10 20 30
1200 A
GV2ME32
224.
GV2P32
278.
9–13
12–18
0.5 1.5
0.75 2
3
5
3 7.5 10
5 7.5 10
——
GV3P13
404.
New! GV3P18
404.
17–25 1.5 3 7.5 7.5 15 20
——
GV3P25
404.
23–32 2 3 10 7.5 20 25
——
GV3P32
404.
30–40 3 5 10 10 25 30
——
GV3P40
504.
37–50
3 7.5 15 10 30 40
——
GV3P50
504.
48–65 3 10 20 15 40 50
——
GV3P65
504.
a For spring terminals add 3 to the catalog number, for example, GV2ME013. GV2ME32 is not available with spring terminals.
GV3P
GV7RE20
Table 18.125:
Thermal
Setting
(A)
Maximum Horsepower Ratings
1Ø 3Ø
115 V 230 V 200 V 230 V 460 V
hp hp hp hp hp
575 V
hp
12–20
15–25
25–40
30–50
48–80
60–100
90–150
132–220
— — — 5 10 15
— — — 7.5 15 20
— — — 10 30 30
— — — 15 30 40
— — — 30 60 75
— — — 30 75 100
— — — 50 100 150
— — — 75 150 200
Toggle Operator
Standard Interrupt
High Interrupt
Catalog
Number
GV7RE20
GV7RE25
GV7RE40
GV7RE50
GV7RE80
GV7RE100
GV7RE150
GV7RE220
$ Price
417.
417.
417.
417.
417.
456.
502.
502.
Catalog
Number
GV7RS20
GV7RS25
GV7RS40
GV7RS50
GV7RS80
GV7RS100
GV7RS150
GV7RS220
$ Price
813.
813.
813.
813.
813.
891.
978.
978.
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-36
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-34 to 18-35
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55
E164864
CCN NLRV
LR81630
Class 3211 05
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-33
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

1 Page





GV2P01 pdf, ピン配列
Starters Accessories
TeSys® Manual Starters and Protectors LS1 Fuseholders
Refer to Catalog 2502CT0001 wwww.wDwa.tsacShhneeeidt4erU-e.cleocmtric.us
45 mm wide (same dimensions as GV2ME)
Available with screw clamp and spring type terminals
Mounts directly to LC1D09–D32 contactors (with use of GV2AF3 or GV2AF4)
Meets application needs for fusible starter
Uses GV2AE instantaneous contact blocks to open control circuits
DIN rail mounted
LS1D30
Table 18.133:
Description
Fuse Type
Dimensions
IN mm
Spring terminals, 3-pole
Screw clamp terminals, 3-pole
CC, KTK-R
CC, KTK-R
0.41 x 1.5
0.41 x 1.5
10.3 x 38
10.3 x 38
Spring terminals, 3-pole
aM, gG
0.39 x 1.5
10 x 38
Screw clamp terminals, 3-pole
aM, gG
0.39 x 1.5
10 x 38
Auxiliary main pole adder
aM, gG
0.39 x 1.5
10 x 38
a Can be mounted on left-hand or right-hand side of the 3-pole LS1D32 block.
Use In
US Markets
US Markets
European Markets
European Markets
European Markets
Catalog Number
LS1D303
LS1D30
LS1D323
LS1D32
LA8D324a
$ Price
86.
86.
101.
86.
65.
Table 18.134: Specifications
Type
Max. voltage
Max. current
Conforming to standards
Product approvals
Protective treatment
Ambient air temperature
—operation
Wiring
Number of conductors and cross sectional area (c.s.a.)
Solid cable
Flexible cable without cable end
Flexible cable with cable end
Resistance to mechanical impact conforming to IEC 60947-1 §7-1-6
Tightening torque
Sensitivity to phase failure
LS1D30, LS1D303
LS1D32, LS1D323, LS1DT32
600 V 3 Phase
30 A
IEC 60947-1, 60947-2, 60947-4-1, EN60204, BS4841, UL 508,
CSA 222.2 No. 14, NFC 63-650, 63-120, 79-130, VDE 0113, 0660
UL, CSA
BV
“TH”
-58 to 158o F
(-50 to +70o C)
“TH”
Max.
2–#8 AWG (2–6 mm2)
2–#8 AWG (2–6 mm2)
2–#10 AWG (2–4 mm2)
0.5 J
15 in-lb (1.7 N•m)
No
Min.
2–#16 (2–1 mm2)
2–#14 (2–1 mm2)
2–#16 AWB (2–1 mm2)
Table 18.135: Specifications
Operating Positions:
30 30
File E164864
CNN NLRV
File LR81630
Class 3211 05
Rated voltage—600 V
Rated thermal current—25 A (GV2), 63 A (GV3)
Mechanical life:
GV2:
100,000 operations
Shock resistance—30 g (conforming to IEC 600 68-2-27)
Vibration resistance—5 g (5 to 150 Hz) (IEC 600 68-2-26)
Ambient temperature:
-40 to 176oF (-40 to +80oC) for storage
-4 to 140oF (-20 to +60oC) open operation
-4 to 104oF (-20 to +40oC) enclosed operation
Maximum operating life—25 operations per hour
Operating current of magnetic trip is approximately 13 times maximum
thermal trip (non-adjustable setting)
18-36
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com


3Pages


GV2P01 電子部品, 半導体
Dimensions
www.schneider-electric.us
GV2M with GK2AF01 and LC1K
GV2M with GV2AF01 and LC1K
TeSys® Manual Starters and Protectors
Refewr wtowC.DaatataloShge2et542U0.cCoTm0001
GV2M with GV2AF01 and LC2K
dimensions in mm
Adapter plate GK2AF01
Ø5.5
.22
45
1.77
79
3.11
Mounting external operator GV2AP0
45
1.77
90 24 9.5
3.54 .94 .37
Door cut-out
4xØ3.5 Ø43
0.14 1.7
GV2M on panel with GV2AF02 adapter
plate
4.2
.17
54
2.13
7.5 mm height compensation plate
GV1F03
1.5...5/0.06...0.20
53 min.=150 max.=290
2.1 5.91 11.42
5.2
0.21
==
Sets of bus bars, GV2G445, GV2G454, GV2G472
with terminal block GV2G05
.12 l
3
p
==
54
2.13
80
3.15
35
1.38
Sets of bus bars with terminal block GV1G09
13 35
0.51 1.38
Sets of bus bars GV2G245, GV2G254,
GV2G272
l
GV2G445
GV2G454
GV2G472
1.8
45
0.16 x 1.8" (4 x 45 mm)
0.16 x 2.1" (4 x 54 mm)
0.16 x 1.8" (4 x 45 mm)
I
7.0" (179 mm)
8.1" (206 mm)
10.2" (260 mm)
P
1.8" (45 mm)
2.1" (54 mm)
2.8" (72 mm)
Dimensions
GV2G245
GV2G254
GV2G272
GV2G354
GV3 P
(1)
(2)
0.08 x 1.8" (2 x 45 mm)
0.08 x 2.1" (2 x 54 mm)
0.08 x 2.8"(2 x 72 mm)
0.12 x 2.1" (3 x 54 mm)
I
3.5" (89 mm)
3.9" (98 mm)
4.6" (116 mm)
6.0" (152 mm)
Mounting on rail AM1 DE200 or AM1 ED201
136 55
X1 = Electrical clearance (ISC max)
40 mm for Ue < 500 V, 50 mm for Ue < 690 V
Mounting on panel, using M4 screws
3xØ4
9 18
144
Blocks GV ANpp , GV ADpp , GV AM11
Block GV3 AUpp and GV3 ASpp
Mounting on pre-slotted mounting plate AM1 PA
AF1 EA4
183
136 37,5
136 18,7 18,7
Note: Leave a space of 9 mm between 2 manual motor protectors: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible: please consult your regional
sales office.
© 2009 Schneider Electric
All Rights Reserved
18-53
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

6 Page



ページ 合計 : 6 ページ
 
PDF
ダウンロード
[ GV2P01 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
GV2P01

Manual Starter and Protector

Steven Engineering
Steven Engineering
GV2P02

Manual Starter and Protector

Steven Engineering
Steven Engineering
GV2P03

Manual Starter and Protector

Steven Engineering
Steven Engineering
GV2P04

Manual Starter and Protector

Steven Engineering
Steven Engineering


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap