DS850-9 Datasheet, DS850-9 PDF,ピン配置, 機能
Embedded Power for
Business-Critical Continuity
DS650/DS850
650 / 850 Watts
Distributed Power System
Distributed Power Bulk Front-End
Total Output 650/850 Watts
Power:
+3.3 Vdc Stand-by Output
Wide Range 90 - 264Vac
Input Voltage: 12, 24 and 48V
Rev. 05.29.08
DS650 and DS850
1 of 4
Special Features
• Active power factor correction
• EN61000-3-2 harmonic compliance
• Active AC inrush control
• 1U X 2U form factor
• 15.4W/ in3
• 12 Vdc, 24 Vdc and 48 Vdc output
• +3.3 Vdc stand-by
(5V standby - consult factory)
• No minimum load required
• Hot plug operation
• N + 1 redundant
• Internal OR'ing fets
• Active current sharing
(10 - 100% load)
• Built-in cooling fans
(40mm x 28mm)
• I2C communication interface bus
• EERPOM for FRU data
• Red/Green bi-color LED status
• Internal fan speed control
• Fan Fail Tach output signal
• INTEL, SSI Std. logic timing
• INTEL, SSI Std. FRU data format
• One year warranty
Safety
UL/cUL 60950 (UL Recognized)
NEMKO+ CB Report EN60950
EN60950
CE Mark
China CCC
Electrical Specifications
Input
Input range
90-264 Vac (wide range)
Frequency
47-63 Hz, single phase AC
Inrush current
Efficiency
Conducted EMI
55 A maximum inrush current
>82% typical at full load, high line
FCC Subpart J EN55022 Class B
Radiated EMI
Power factor
FCC Subpart J EN55022 Class B
0.99 typical
Leakage current
1.40 mA @ 240 Vac
Hold up time
20ms minimum
Output
Main DC voltage
Stand-By
+12 V @ 52.5 A/70.0 A
+24 V @ 26.3 A / 35.0 A
+48 V @ 13.1 A / 17.5 A
+3.3 vsb @ 6 A (5 V @ 4 A available)
Adjustment range
Factory Set, no pot adjustments
Regulation
Over current
Over voltage
Under voltage
Turn-on delay
Main output rise time
Main output; +5%/-5%
+3.3 vsb; +5%/-5%
110% - 150% of nominal Latches off if overcurrent lasts
over 1 second, otherwise it is auto recovery.
+3.3 vsb, 9 A max (hiccup mode)
110% - 120% of nominal
+3.3 vsb; 3.76 - 4.30 Vdc
75% - 90% of nominal
2 Second max, 5 - 50 mS, Monotonic Rise
5 - 50 mS, Monotonic Rise

1 Page





DS850-9 pdf, ピン配列
Mechanical Drawing
Power Supply Condition
LED
Green/Amber
No AC power to all PSU
OFF
AC present/Standby outpus ON,
Main output OFF
Blinking Green
Power supply DC outputs ON and OK Solid Green
Main output failure (OCP, OVP, UVP) Blinking Amber
Fan Fail, OTP, Standby output OCP/UVP Solid Amber
1.58"
(40.2)
CLIP COMPRESSED
BI-COLOR LED
.638" ±.02"
(16.2 ±0.6)
.897" ±.02
(22.8 ± 0.6)
(2X)
3.30" ±.03"
(83.8 ±0.7)
Embedded Power for
Business-Critical Continuity
Rev. 05.29.08
DS650 and DS850
3 of 4
3.09"
(78.5)
.649
(16.5)
AIRFLOW DIRECTION
(3X) 3.09"
(78.5)
7.48"
(190.0)
11.0" ± .02"
(279.4 ±0.5)
.315"
(8.0)
.275"
(7.0)
SEE NOTE 3
(65.5)
(40.5)
(15.5)
3.09"
(78.5)
10.85" ±.03"
(275.5 ±0.7)
.767"
(19.5)
3.20" ±.02"
(81.3) ±0.5
1.60"
(40.7)
.142" ±.02" 1.57" ±.02"
(3.6 ±0.5) (39.9 ±0.5)
.354"
(9.0)
.236"
FULL R .256" (6.0)
(6.5)


3Pages





ページ 合計 : 4 ページ
 
PDF
ダウンロード
[ DS850-9 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
DS850-3

AC-DC / Distributed Power Front-End 1U

Emerson
Emerson
DS850-3-002

AC-DC / Distributed Power Front-End 1U

Emerson
Emerson
DS850-5

AC-DC / Distributed Power Front-End 1U

Emerson
Emerson
DS850-9

AC-DC / Distributed Power Front-End 1U

Emerson
Emerson


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap