Shenzhen Sunyuan Technology Co.,Ltd.
ISO 4011 Series
Multirange,High Accuracy Analog Input,
Data Acquisition Modules
Features
Single-channel analog signal-conditioning modules,isolated RS-485/232 output
Testing accuracy>0.05%
Can be remotely reconfigured for modules accuracy and input ranges
Three-port isolation(input/output/assistant power supply): 3000VDC
Power supply:24VDC/15VDC/12VDC/5VDC
High reliability,easy programme,installation.
Temperature sensors for offsetting thermocouple cold port
J/ K/ T/ E/ R/ S/ B thermocouple input
±15 mV/ ±50 mV/ ±100 mV/ ±500 mV millivolt small signal input
±1 V / ±2.5 V voltage signals or ±20 mA current signals input
Applications
Temperature signal testing/monitoring/cintrol
RS-232/485 industrial automation control system
Industial field signal isolation
Process Monitoring & Control
Test sensors signal
Laboratory Data Acquisition
Medical machine monitoring
4-20mA/0-20mA signal acquisition
Product Overview
ISO40xx series realizes sensor-to-host signal acquisition for testing analog signal or remote
applications. Software-configurable for a wide variety of sensor types, including: analog
input, analog output, and digital I/O,ISO40xx series are widely used in RS-232/485
automation control system,temperature signal testing,small signal testing, Monitoring &
Control, remote data acquisition applications.
Including power supply isolation, signal isolation, linearization, A/d conversion and
RS-232C/RS-485 serial communication. for up to 256 channels per serial port, ISO40xx Series
modules,adopts ASCII format and MODBUS,its injunction fully encapsulated to ADAM
modules,baud rate can be intercalated by code,can be used in the same RS-485 lines with other
manufacturers modules,convenient for computer-programme.
ISO40xx series modules is SCM-based intelligent monitoring and control system, with all
calibration,High and Low alarm, address,input ranges,baud rate,data format and linearizing
parameters stored in EEPROM non-volatile memory. ISO 40xx series modules can test
variety of sensor types,including thermocouple and RTD ,and other a wide variety of input
ranges,different modules that need to be used in a given application and carried in
inventory.
ISO40xx series modules are designed as industrial standard,three-port isolation
(input/output/power supply),3000VDC isolated.Temperature range is - 45to +85.
Page 1 of 22

1 page




ISO4011 pdf
www.DataSheet4U.com
16
Shenzhen Sunyuan Technology Co.,Ltd.
PW- Power -
Note 1:when output is RS-232output connection refer to
Figure 2
Note 2:when output without alarm,13,14 are NO Pin.
Do0Do1 is switching output port,wiring diagram refer to
Figure 1.when alarm, Do0Do1 audion pass.
Wiring Diagram
Module connecting refer to Figure 1.Broken line divides module
Into three isolated parts:Signal input,RS-485/RS-232 interface
/assistant power supply and alarm output.Power supply and
Alarm output are been connected into interiorly,when products w
With alarm function.Limit resistance R is used to limit current.
Max.:100mA,suggest current value:5~10mA
Figure 2 ISO 4011-P-A and RS-232 Wiring Diagram
RS-232 Interface
When part No. is ISO 4011-P-B(or AB)user can choose RS-485 output or RS-232 output
by internal keyswithch.Open product’s coping,may see two button switching in the board,all
aren’t pressed is RS-485 output,two pressed is RS-232 output.When choose RS-232
output,please refer to Figure 2,9,10,12 separately connects to RS-232 interface
RXD,TXD,GND.
Alarm Signaling
ISO 4011-P-A(or AB) analog input modules include High and Low alarm functions.
High and Low alarm limits may be downloaded into the module’s EEPROM by the host
computer.
The alarm functions can be enabled or disabled remotely. When the alarm function is
enabled, both Digital Output channels are used to indicate the High and Low alarm state.
Digital Output channel 1 (DO1) equals to High alarm state, and Digital Output channel 0
(DO0) equals to Low alarm state. The High and Low alarm states can be read at any time by
the host computer.
Every A/D conversion will be followed by a comparison with the High and Low limit.
Page 5 of 22

5 Page





ISO4011 arduino
www.DataSheet4U.com
Shenzhen Sunyuan Technology Co.,Ltd.
! delimiter character which indicates a valid command.
? delimiter character which indicates a invalid command.
AA represents input module address
(cr) terminating character, carriage return (0Dh)
If you configure module for the first time,AA=00NN equals to new address.If reconfigure
module changing address,input range,data formats,AA equals to present or new address.If
reconfigure module changing baud rate or checksum state, must install command
string,make them in listening mode,module address is 00H,also AA=00H,NN=present or
new address.
There is no response if the module detects a syntax error or communication error or if the
specified address does not exists.
Example: command %0011050600(cr)
Response !11(cr)
Description: % delimiter character
00indicates analog input module initial address that you want to set is 00H
11 indicates new module hexadecimal address is 11H
05 indicates input range:±2.5 V
06 indicates baud rate:9600 baud
00 indicates data format is Engineering Unitschecksum is disabled
5Read Set State Command
Description: Read set for the specified a analog input module.
Syntax: $AA2(cr)
$ delimiter character
AA module address, (range 00-FF) represents the 2-character hexadecimal
2 indicates read set state command
(cr) terminating character, carriage return (0Dh)
Response: !AATTCCFF(cr) command is valid
?AA(cr)
command is invalid or nonlicet operation
! delimiter character
AA represents input module address
TT Type Code,Table 5
CC Baud rate code,Table 3
FF Table 4
(cr) terminating character, carriage return (0Dh)
There is no response if the module detects a syntax error or communication error or if the
specified address does not exists.
Example: command $302(cr)
Response !300F0600(cr)
! delimiter character
30 indicates analog input module address is 30H
0F indicates that input is K,testing range is 0℃~1000
06 represents that baud rate is 9600 baud
00 represents that data format is Engineering Units,disable checksum
Page 11 of 22

11 Page







PáginasTotal 22 Páginas
PDF Descargar[ Datasheet ISO4011.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
ISO4011one-channel Data Acquisition ModulesShenzhen Sunyuan
Shenzhen Sunyuan
ISO4014four-channel Data Acquisition ModulesShenzhen Sunyuan
Shenzhen Sunyuan

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar