FEATURES
1. High-capacity and long life
Mechanical life is more than 10 million
operations and, with electrical life of more
than 200,000 operations (resistive load
10 A; inductive load 7.5 A), the relay has
excellent inductive load durability.
2. Easy mounting and wiring
The terminal arrangement is apparent at
a glance and wiring is easy. Moreover,
quick tab terminal is also possible.
3. Operation indicator option
Optional operation indicators are
available for easy visual confirmation that
relays are operating. They simplify
maintenance.
4. UL/CSA approved
5. Wide range of sockets and terminal
sockets
To enable use with DIN rails, DIN
terminal sockets are also available.
TYPICAL APPLICATIONS
HP relays enjoy wide use in various
applications, particularly in automation
controls and remote controls.
Applications include:
1. Industrial machinery
For controlling positioning, pressure, and
temperature in molding equipment,
boilers, pumps, charging pressure
equipment, measuring and evaluation
equipment, textile machines, etc.
2. Machine tools
Control of positioning and directional
change in turning machines, lathes,
borers, etc.
3. Food processing packing machines
Automatic control of packing equipment
for milk and seafood, bottling, canning,
and packaging
4. Office equipment
Control of copiers, time recorders, etc.
5. Coin operate machines
Control of food, cigarette, and other
vending machines
6. Transportation
Amplification of control signals in control
devices for vehicles and vessels,
functional parts of all kinds of equipment,
control signal repeating installation in
signaling devices and equipment.
7. Measuring devices and equipment
For repeating installation of control
signals and in power amplifiers
8. Generators, transformers and
power receiving equipment.
Functional parts in protective equipment,
functional assistance in automatic
adjustment equipment, telemeters and
other remote monitoring equipment
9. Control of conveyance equipment
Control panels for elevators, escalators,
and other conveyance equipment, control
of all kinds industrial transport equipment
such as conveyors.
10. Amusement equipment
Control of equipment in amusement
parks, etc., control of bowling alley
equipment, control of fountains in public
parks
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances. (The suffix “F”
should be added to the part number. The
Suffix “F” is required only for 4 Form C
contact type. The 2 Form C and 3 Form C
contact type is originally cadmium-free,
the suffix “F” is not required.)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

line_dark_gray
HP2-AC220V equivalent
Including discontinued products (
)
HP
www.2D.aStapSehceiet4cUa.tcioomns
Characteristics
Contact
Rating
Item
Arrangement
Initial contact resistance, max
Contact material
2 Form C, 3 Form C
4 Form C
Nominal switching capacity
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Electrical
characteristics
Between open contacts
Breakdown voltage
(Initial)
Between contact sets
Between contact and coil
Temperature rise
Operate time*2
Mechanical
characteristics
Expected life
Conditions
Unit weight
Release time*2
Shock resistance
Vibration resistance
Mechanical
Functional
Destructive
Functional
Destructive
Conditions for operation, transport and storage*3
Max. Operating speed
Specifications
2 Form C, 3 Form C, 4 Form C
Max. 15 m(By voltage drop 6 V DC 1A)
Ag
Ag alloy (cd free)
10A 250V AC (resistive load)
100mA 5V DC
Min. 100M(at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
1,500 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
1,500 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
Max. 65°C (By temperature method, at 40°C, nominal current)
Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2 mm
Min. 107
Ambient temperature: –50°C to +40°C –58°F to +104°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm (at max. rating)
2 Form C: approx. 60g 2.12oz, 3 Form C: approx. 100g 3.53oz, 4 Form C: approx. 125g 4.41oz
Notes: *1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 For the AC coil types, the operate/release time will differ depending on the phase.
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to 6. Conditions for operation,
transport and storage mentioned in AMBIENT ENVIRONMENT.
3. Electrical life
1) AC load
Voltage
Load
125V AC
Resistive (A) (cosϕ=1)
Inductive (A) (cosϕ=0.4)
250V AC
Resistive (A) (cosϕ=1)
Inductive (A) (cosϕ=0.4)
— — 10 7.5
10 7.5 7.5
Current
533
5
2
1 0.7 0.6 0.4
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
Expected life
Min. 2×105
Min. 5×105
Min. 106
Min. 2×106
2) DC load
Voltage
24V DC
Load
Resistive (A)
Inductive (A)
—7
Current
7.5
5
5
3
1 0.6
Note: For DC inductive loads, use an arc suppressing circuit.
Resistive (A)
0.5
0.3
0.1
125V DC
Inductive (A)
0.4
0.2
0.06
Expected life
Min. 2×105
Min. 5×105
Min. 106
Min. 2×106
Note: Cautions at DC load use
When used under a DC load operating at high repetition rate with considerable arcing, corrosion of the contacts and/or the contact blades is likely to occur.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


line_dark_gray

Preview 5 Page


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for HP2-AC220V electronic component.


Information Total 13 Pages
Link URL [ Copy URL to Clipboard ]
Download [ HP2-AC220V.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
HP2-AC220VThe function is 10 AMP POWER RELAY. PanasonicPanasonic

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

HP2-     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search