DeviceNetTM Option Card
CM053, CM056, CM057, CM058
! This document applies to the Yaskawa GPD515/G5, F7, G7 and P7 drives.
! Unpack the DeviceNet Option (CM05x) and verify that all components are present and undamaged. Check the EPROM label
to verify that the DeviceNet Option (CM05x) card is the correct card for the drive.
wwwD.rdivaetasheetK4iut.Ncoummber
G5 CM053
Option Board Number
46S03318-001x
EPROM Label Designation
VST80007x
Qty.
1
F7 CM056
46S03318-002x
VST80003x
1
G7 CM057
46S03318-003x
VST80004x
1
P7 CM058
46S03318-004x
VST80005x
1
DeviceNet Option (CM05x) Installation Guide (IG.AFD.14)
1
! Connect power to the drive and verify that the drive functions correctly. This includes running the drive from the operator keypad. Refer to the appropriate drive technical
manual for information on connecting and operating the drive.
! Remove power from the drive and wait for the charge lamp to be completely extinguished. Wait at least five additional minutes for the drive to be completely discharged.
Measure the DC BUS voltage and verify that it is at a safe level.
! Remove the operator keypad and drive cover.
# Remove the operator keypad and loosen any screws on the front of the terminal
cover. Simultaneously pushing the locking tabs on the bottom right and left sides of
the terminal cover inward, pull the bottom edge of the terminal cover outward.
# Loosen any screws on the front of the control cover. Simultaneously pushing the
locking tabs on the bottom right and left sides of the control cover inward, pull the
bottom edge of the control cover outward. The drive control card should be visible.
# Remove the option card hold-down on the left side of the drive case by carefully
compressing the top and bottom until it becomes free of its holder. Lift it out.
! Mount the DeviceNet Option (CM05x) on the drive.
# Align the J1 connector on the back of the DeviceNet Option (CM05x) with its
mating 2CN connector on the drive control card.
# Align the three standoffs on the front of the drive control board with the three holes
on the right side of the DeviceNet Option (CM05x).
# Press the DeviceNet Option (CM05x) firmly onto the drive 2CN connector and
standoffs until the J1 connector is fully seated on 2CN and the drive standoffs have
locked into their appropriate holes.
# Replace the option card hold down.
# Connect the ground wire from the ground terminal E on the option card to a ground
terminal on the terminal assembly.
! Apply power to the drive and verify that the drive functions correctly.
! Connect to the DeviceNet network as shown in the figure to the right.
Terminal Name Wire Color
Description
1
V- Black
Communication GND
2 CAN_L Blue
CAN Data Low
3 Shield Bare
Cable Shield
4 CAN_H White
CAN Data High
5 V+ Red
Communications +24Vdc
Mounting the DeviceNet Option on an F7 drive
Yaskawa Electric America, Inc – www.drives.com
IG.AFD.14, Page 1 of 4
Date: 07/01/04, Rev: 04-07

1 Page





CM058 pdf, ピン配列
! Install the EDS File and Configure the Drive on the DeviceNet Network
The EDS file can be obtained from the CD that was included with the drive or downloaded from www.drives.com. It is recommended that the EDS file be downloaded
from www.drives.com to be sure that the latest version is used. Install the EDS file into the DeviceNet configuration tool (i.e. RSNetworxfor DeviceNet). There is a
separate EDS file for each drive model, verify that the correct EDS file has been installed for the drive model configured. Refer to the documentation that came with the
master configuration tool for information on installing EDS files and configuring a DeviceNet node.
Note: The EDS files located on the CD or downloaded from www.drives.com will be in “zip” format and will need to be un-zipped to a temporary directory prior to
installation.
www.datasheet4u.com
! LED Status Indicators and Diagnostics
MS LED
Condition
Off Power Off
Flashing Red Minor Fault
Solid Red
Unrecoverable Fault.
Flashing Green In Standby
Solid Green
Normal – Communicating
NS LED
Condition
Off
Flashing Red
Power Off
Incomplete Initialization
Connection Time-Out
Solid Red
Critical Link Failure
Flashing Green Normal – Not Communicating
Solid Green
Normal – Communicating
Solution
# Check the drive main circuit wiring
# Check the connection of the option board to the 2CN connector on the drive
# Turn power on
# Check network termination
# Check network wiring
# Check baud rate
# Check that the communication bus wiring is separated from the main circuit wiring
# Check if MAC ID is unique per the network
# Check baud rate
# Check if the master is correctly configured
# Check if the termination resistors are correctly connected to the communication bus
# Check if the communication device is correctly connected per wiring diagrams
# Check if the communication bus wiring is separated from the main circuit wiring
# Check that the DeviceNet master has been configured for the drive
-
Solution
# Check the drive main circuit wiring
# Check the connection of the option board to the 2CN connector on the drive
# Turn power on
# Wait for initialization to complete
# Check that the DeviceNet master is connected and on-line
# Check if MAC ID is unique per the network
# Check baud rate
# Check that the DeviceNet master is configured correctly
# Check that the termination resistors are correctly installed at the ends of the communication bus
# Check that the communications bus is not terminated any place other than at the ends
# Check that the drive is correctly connected per wiring diagrams
# Check that the communication bus wiring is separated from the main circuit wiring
# DeviceNet master is in “idle” mode
# Send an explicit or I/O message from the master as necessary
Yaskawa Electric America, Inc – www.drives.com
IG.AFD.14, Page 3 of 4
Date: 07/01/04, Rev: 04-07


3Pages





ページ 合計 : 4 ページ
 
PDF
ダウンロード
[ CM058 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
CM053

(CM053 - CM058) Option Card

Yaskawa
Yaskawa
CM056

(CM053 - CM058) Option Card

Yaskawa
Yaskawa
CM057

(CM053 - CM058) Option Card

Yaskawa
Yaskawa
CM058

(CM053 - CM058) Option Card

Yaskawa
Yaskawa


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap