DataSheet.jp

HIS-07 の電気的特性と機能

HIS-07のメーカーはHanweiです、この部品の機能は「Ionization Smoke Chamber」です。


製品の詳細 ( Datasheet PDF )

部品番号 HIS-07
部品説明 Ionization Smoke Chamber
メーカ Hanwei
ロゴ Hanwei ロゴ 




このページの下部にプレビューとHIS-07ダウンロード(pdfファイル)リンクがあります。

Total 3 pages

No Preview Available !

HIS-07 Datasheet, HIS-07 PDF,ピン配置, 機能
HANWEI ELECTRONICS CO.,LTD
Http:www.hwsensor.com
www.DataSheet4U.com
HIS-07 SPECIFICATIONS
1SCOPE
This specification sheet is for ionization smoke chamber model HIS-07 (radiation source-
0.5microcurie Am-241, 2 chambers with a source, made in compliance with UL 217,
EN-54-7) for applications to smoke detectors.
2. Radiation source:
Nuclide ; americium 241
Radioactivity;Ave.33.3 KBq. =0.9μ CI(29K~37KBq)
3.Operational conditions:
Power supply; DC9V
Operational ambient conditions;
Temperature 0--50
Humidity
less than 95 (No dew
condensation)
4.Maximum ratings:
Supply voltage; DC 24V
Operation; Temperature -10…+60
Humidity less than 95%
Storage;
Temperature -25…+80
Humidity less than 95%
6.Shape,dimensions, weight;
Shape;
As per attached drawing
Dimensions; 22.0×Ф 42mm
Weight;
12g.
7.Ratings:
Test conditions; at 25,60% RH
Items
Supply voltage
Current consumption
Output voltage
Sensitivity
specifications
DC 9V
27±3pA
5.6±0.4 V in clean air
0.6 ± 0.1 V at 2%/foot of
smoke
(Tested according to UL 217)
8.Characteristics:
8-1.Sensitivity characteristics
Table 1
Smoke
concentration(%/foot)
0
1
2
3
4
5
Test conditions ;at 25,60% RH
output
Variation (V)
5.6±0.4
5.3±0.5
5.0±0.5
4.7±0.5
4.4±0.5
4.2±0.5
0
0.3±0.1
0.6±0.1
0.9±0.2
1.2±0.2
1.4±0.2
TEL:86-371-67169070 67169080
FAX:86 371 67169090

1 Page





HIS-07 pdf, ピン配列
HANWEI ELECTRONICS CO.,LTD
Http:www.hwsensor.com
wooden plate with 3 different directions .
www.DataSheet4U.com
Heading No.8 after test .To show neither
deforming , nor discoloring , nor cracks .
10. Remarks
10.1 Output voltage is to be measured using an electrometer with more than 1014 of
impedance or an exclusively designed measuring circuit with Ics . Normal testers with
around 100MΩ impedance would be insufficient for measurement .
10.2 Upon assembling detectors ,attention is to be paid not to let a soldering flux get
inside smoke chambers .If inside of the chambers is contaminated ,cleaning or washing
is necessary .
10.3The output lead wire of a chamber and an input terminal of a circuit must be
connected in air to keep the connected point away from the surface of a PC
board(usually a teflon pin is used to support the connected point) .Because of the
resistance level of paper phenol PC boards , current leakage will occur on to the PC
board . This will prevent to read correct outputs .
10.4 The connected point of the lead wire and the input terminal of an FET or an IC must
be protected from humidity using a silicon resin or the like so that current leakage from
the packages will be minimized .
10.5 Because of the necessity of reading a tiny current put out from the chamber ,this
sensor must be electrically shielded to minimize noises from the outside .As the most
sensitive part to noises is the connected part of the lead wire and the input the terminal
of a circuit ,this part must definitely be shielded .
TEL:86-371-67169070 67169080
FAX:86 371 67169090


3Pages





ページ 合計 : 3 ページ
 
PDF
ダウンロード
[ HIS-07 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
HIS-0169C

HIS-0169C

ETC
ETC
HIS-07

Ionization Smoke Chamber

Hanwei
Hanwei
HIS-07

Fire Detection Systems

ETC