www.DataSheet4U.comS7-300 Module Specifications, Edition 11/2002, (A5E00105505-02)
Introduction
The S7-300 product family has been enhanced and improved. This document
contains details of the features and technical specifications of the modules.
Contents
Section
1
2
3
4
Contents
Analog input module SM 331; AI 8 x 13 Bit;
(6ES7 331-1KF01-0AB0)
Parameters of the SM 331; AI 8 x 13 Bit
Measuring Methods of the SM 331; AI 8 x 13 Bit
Parameters of the SM 331; AI 8 x 13 Bit
Page
2
6
7
8
Copyright 2003 by Siemens AG
A5E00236204-01

1 Page





S7-300 pdf, ピン配列
Terminal Assignment and Block Diagram of the SM 331; AI 8 13 Bit
On channels 4 to 7 in the figure below you will find a number of connection
examples for the different measuring methods. These connection examples can be
applied in the same way to all channels (channels 0 to 7).
www.DataSheet4U.com
00
11
22
33
44
55
66
77
00
11
22
33
44
55
66
77
Channel
number
U+ 1
I+
S
Ch 0 M+
2
3
4
M5
U+ 6
I+ 7
S8
Ch 1
M+ 9
M10
U+ 11
I+ 12
Ch 2 S13
M+ 14
M15
U+ 16
I+ 17
S18
Ch 3
M+ 19
M20
Connection examples
Multiplexer
Logic
circuitry
and
backplane
bus
interface
module
Isolation
ADC
Current
source
+ 5 V from
backplane bus
Internal supply
21 U+
22 I+
23 S
V Ch 4
24 M+
25 M
26 U+
27 I+
28 S
29 M+
30 M
A
Ch 5
31 U+
32 I+
33 S
Ch 6
34 M+
mV
35 M
36 U+
37 I+
38 S
39 M+
40 M
Ch 7
Figure 1 Module View and Block Diagram of the SM 331; AI 8 13 Bit
Note
When connecting voltage and current sensors, ensure that the maximum
permissible common mode voltage UCM of 2 V is not exceeded between the
inputs. To prevent incorrect measurements being made, you should therefore
connect the different Mconnections to each other.
When measuring resistances and resistance thermometers, the Mconnections
do not have to be interconnected.
Product Information on the Manual S7-300 Module Specifications, Edition 11/2002,
(A5E00105505-02)
A5E00236204-01
3


3Pages


S7-300 電子部品, 半導体
Connection of the sensor
S For measuring
voltage
S For measuring current
As two-wire transmitter
As four-wire transmitter
S For measuring
resistance
www.DataSheet4U.com
With 2-conductor
terminal
With 3-conductor
terminal
With 4-conductor
terminal
Possible
Possible, with external
supply
Possible
Possible
Possible
Possible
Characteristic linearization
S For resistance
thermometer
S Technical unit for
temperature
measurement
Parameters can be
assigned
Pt 100 Standard / Climatic
Ni 100 Standard / Climatic
Ni 1000 Standard /
Climatic LG-Ni 1000
Standard / Climatic
Degrees Celsius,
degrees Fahrenheit,
Kelvin
2 Parameters of the SM 331; AI 8 13 Bit
Parameter
Section 4.7 of the reference manual describes how the analog modules are
generally parameterized.
An overview of the parameters that you can set and their default settings are
shown in the table below.
Product Information on the Manual S7-300 Module Specifications, Edition 11/2002, (A5E00105505-02)
6 A5E00236204-01

6 Page



ページ 合計 : 10 ページ
 
PDF
ダウンロード
[ S7-300 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
S7-300

Programmable Controllers Module Specifications

Siemens
Siemens
S7-300

Programmable Controller Hardware and Installation

Siemens
Siemens
S7-300

CPU 31xC and CPU 31x

Siemens
Siemens
S7-300

Module Spectfications

Siemens
Siemens


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap