DataSheet.jp

E5CSZ の電気的特性と機能

E5CSZのメーカーはOmronです、この部品の機能は「Temperature Controllers」です。


製品の詳細 ( Datasheet PDF )

部品番号 E5CSZ
部品説明 Temperature Controllers
メーカ Omron
ロゴ Omron ロゴ 




このページの下部にプレビューとE5CSZダウンロード(pdfファイル)リンクがあります。

Total 20 pages

No Preview Available !

E5CSZ Datasheet, E5CSZ PDF,ピン配置, 機能
Temperature Controllers
E5CSZ
Easy Setting Using DIP Switch and Simple
Functions in DIN 48 × 48 mm-size
Temperature Controllers
• Easy setting using DIP and rotary switches.
• Models with two alarms added to Series, ideal for temperature
alarm applications.
• Clearly visible digital display with character height of 13.5 mm.
www.DataSheetM4Uo.dceomls available with black or white cases.
• RoHS compliant (Scheduled for January 2006).
Model Number Structure
Model Number Legend
Models with Terminal Blocks
E5CSZ-@@@@-@
1234 5
1. Output type
R: Relay
Q: Voltage for driving SSR
2. Number of alarms
Blank: No alarm
1: 1 alarm
3. Input type
T: Thermocouple/platinum resistance
thermometer (multi-input)
4. Power supply voltage
Blank: 100 to 240 VAC
D: 24 VAC/VDC
5. Case color
Blank: Light gray
B: Black
Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations. Refer to
Ordering Information when ordering.
Example
Relay control output, one alarm output, multi-input, light gray: E5CSZ-R1T.
Temperature Controllers E5CSZ
1

1 Page





E5CSZ pdf, ピン配列
Characteristics
Setting accuracy
Indication accuracy
(ambient temperature of 23°C)
Thermocouple (See note 1.):
(±0.5% of indication value or ±1°C, whichever is greater) ±1 digit max.
Platinum resistance thermometer (See note 2.): (±0.5% of indication value or ±1°C, whichever is greater) ±1 digit max.
Influence of temperature
Influence of voltage
Thermocouple inputs:
(±1% of PV or ±4°C, whichever is greater) ±1 digit max.
Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.
Hysteresis (for ON/OFF control) 0.1% FS for multi-input (thermocouple/platinum resistance thermometer) models
Proportional band (P)
1 to 999°C (automatic adjustment using auto-tuning/self-tuning)
Integral time (I)
1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning
Derivative time (D)
1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)
Alarm output range
Absolute-value alarm: Same as the control range
Other:
0% to 100% FS
Alarm hysteresis: 0.2°C or °F (fixed)
Control period
2/20 s
Sampling period
500 ms
Insulation resistance
20 Mmin. (at 500 VDC)
www.DataSheeDti4eUle.cctorimc strength
2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity
Vibration
resistance
Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions
Shock resistance Malfunction 100 m/s2 min., 3 times each in 6 directions
Destruction 300 m/s2 min., 3 times each in 6 directions
Life expectancy
Electrical 100,000 operations min. (relay output models)
Weight
Approx. 120 g (Controller only)
Degree of protection
Front panel: Equivalent to IP50; Rear case: IP20; Terminals: IP00
Memory protection
EEPROM (non-volatile memory) (number of writes: 1,000,000)
EMC
EMI Radiated:
EN 55011 Group 1 Class A
EMI Conducted:
EN 55011 Group 1 Class A
ESD Immunity:
EN 61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Radiated Electromagnetic Field Immunity: EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3)
10 V/m (900 MHz pulse modulated)
Conducted Disturbance Immunity:
EN 61000-4-6: 3 V (0.15 to 80 MHz) (level 2)
Noise Immunity (First Transient Burst Noise): EN 61000-4-4
Burst Immunity:
2 kV power-line (level 3), 1 kV I/O signal-line (level 3)
Surge Immunity:
EN 61000-4-5: Power line:
Normal mode 1 kV; Common mode 2 kV
Output line (relay output): Normal mode 1 kV; Common mode 2 kV
Voltage Dip/Interrupting Immunity:
EN 61000-4-11 0.5 cycle, 100% (rated voltage)
Approved standards
UL 61010C-1 (listing)
CSA C22.2 No.1010-1
Conformed standards
EN 61326, EN 61010-1, IEC 61010-1
VDE 0106 Part 100 (finger protection), when the terminal cover is mounted.
Note: 1. The following exceptions apply to thermocouples.
L: ±2°C ±1 digit max.
2. The following exceptions apply to platinum resistance thermometers.
Input set values 0, 1, 2, 3 for E5CSZ: 0.5% FS ±1 digit max.
Input set value 1 for E5CSZ: 0.5% FS ±1 digit max.
Electrical Life Expectancy Curve for Relays (Reference Values)
500
300
100
50
30
10
5 E5CSZ
3 250 VAC, 30 VDC
(resistive load)
cosφ = 1
1
01 2 3
4 56
Switching current (A)
Temperature Controllers E5CSZ
3


3Pages


E5CSZ 電子部品, 半導体
Operation
E5CSZ
Deviation indicators
The indicator lights when the PV is greater than
the SP and the indicator lights when the PV is
less than the SP. The indicator (green) lights
when the deviation is less than 0.25% FS. These
indicators flash during ST (self-tuning)/AT (auto-
tuning).
Mode indicators
The SP indicator lights when the setting
www.DatatiSnedhmiecpeaett4roaUrtul.icrgeohmtiss
being
when
displayed. The ALM
the alarm value 1 is
being displayed and flashes when the alarm
value 2 is being displayed.
Mode Key
When the power is turned ON, normally the
display will use the display items in the following
order each time the Mode Key is pressed.
Power ON
E5CSZ
PV
Press the
SP
Press the
Alarm value 1
Press the
Input shift value
Press the
Key.
Key.
Key.
This item is not displayed when
the Control Mode Switch 4 is OFF.
Key.
Lock Release Key
When the protect switch is ON, the set
value can be changed by pressing the Up
and Down Keys while holding down the
Lock Release Key.
Settings before Turning ON the Power
PV, SP, Alarm Value, Input Shift Display
The display switches each time the
Key is pressed.
Output indicator
Lights when the control output is ON.
Alarm indicator
ALM1 (Alarm 1): Lights when the alarm 1
output is ON.
Up Key
Pressing the Up Key increases the
SP/alarm value display. Keeping the Up
Key pressed continues to increase the
display value. When the internal protect
switch is ON, press the Up Key while
holding down the Lock Release Key.
Down Key
Pressing the Down Key decreases the
SP/alarm value display. Keeping the Down
Key pressed continues to decrease the
display value. When the internal protect
switch is ON, press the Down Key while
holding down the Lock Release Key.
E5CSZ
Remove the E5CSZ from the case to make the settings.
1. Insert the tool into the two tool insertion holes (one on the top and
one on the bottom) and release the hooks.
Tool hole
Flat-blade screwdriver
(Unit: mm)
(1)
20 min.
(3)
(2)
(1)
0.4 2.0
2. Insert the tool in the gap between the front panel and rear case,
and pull out the front panel slightly. Grip the front panel and pull
out fully. Be sure not to impose excessive force on the panel.
3. When inserting the E5CSZ, check to make sure that the sealing
rubber is in place and push the E5CSZ toward the rear case until
it snaps into position. While pushing the E5CSZ into place, push
down on the hooks on the top and bottom surfaces of the rear
case so that the hooks are securely locked in place. Make sure
that electronic components do not come into contact with the
case.
Control mode switches
ON ON
Alarm mode switch (See note 1.)
Temperature range switch
PX1 2 3 4 5 6
INIT switch
(See note 2.)
Protect switch
Note: 1. The alarm mode switch is not provided on models without an alarm.
2. The INIT switch is always OFF during normal operation.
6 Temperature Controllers E5CSZ

6 Page



ページ 合計 : 20 ページ
 
PDF
ダウンロード
[ E5CSZ データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
E5CS-X

Temperature Controller

Omron
Omron
E5CSZ

Temperature Controllers

Omron
Omron