BXA15 and BXA30 SERIES
Design Note 100 Rev. 01 - Feb. 1999
• Safety and the low voltage directive
• Electromagnetic Compatibility Immunity
• Electromagnetic Compatibility Conducted and
Radiated Interference
• Telecom and Distributed Power Architecture Features
• System Protection Features
• Thermal Considerations
• Input Impedance Considerations
1. Safety and the Low Voltage Directive
The BXA15 and BXA30 series is intended to be supplied only from a
SELV (Safe Extra Low Voltage) circuit or a TNV (Telecommunications
Network Voltage) power source which are insulated from the AC
mains by reinforced insulation. Basic isolation, tested to 1,500VDC,
for EN60950 and UL1950, is provided.
SELV
TNV
DC Distributed Power of 12V, 24V or 48V
Central Office -48V
2. Electromagnetic Compatibility Immunity
Good design practice dictates that the electronic system be immune
to noise interference. This practice has now been encapsulated in
European law in the form of the EMC directive. It is imperative that
any system on sale in the European Union meets the terms of the
EMC directive and thus carries the CE mark. To simplify system
compliance to the EMC Directive, the BXA15 and BXA30 have been
designed to meet and comply with the necessary immunity stan-
dards.
Description
Electro-Static
Discharge
Standard
EN61000-4-2
Compliance Level
4kV Contact
8kV Discharge
Radiated Immunity
IEC801-3
10V/m
Fast Transients/Bursts
Surges
EN61000-4-4
EN61000-4-5
2kV
0.5KV (40 Ohm
Generator,
Secondary surge
protection)
3. Electromagnetic Compatibility Conducted and
Radiated Interference
Radiated Interference:
The BXA15 and BXA30 series meet the harmonised standard
EN55022 level A and CISPR22 level A. The series almost meets the
requirements of level B. System performance to level B could be
assured with the appropriate enclosure.
Conducted Interference - Level A Internal Filter Option:
All three input voltage versions of the series, 12VDC, 24VDC and
48VDC, are available with an internal filter option which meets input
conducted noise per VDE0871/8-A or EN55022-A. To order a model
with the internal filter, add ‘-F’ after the model number eg. BXA15-
48S12-F.
Conducted Interference - Level B External Filter:
The addition of an external capacitor enables the BXA15 and
BXA30 products to meet VDE0871/8-B, EN55022-B and CISPR22-B
conducted noise limits. The test set-up is per VDE 0877 Part 1 fig.4
with the load < 10 cm's away from the test converter.
Input Voltage
48 Volt
24 Volt
12 Volt
Recommended External Cap.
Nippon Chemi-Con SXE series120uF, 100V
ITW PAKTRON Capstick series part number
405K100CS4, 4uF @ 100V
ITW PAKTRON 405K100CS4
2 * ITW PAKTRON 405K100CS4
capacitors in close parallel.
For height critical applications, the ITW Paktron capacitor offers a
low profile of <7mm.
Note on the test set up and system grounding:
The products meet input conducted noise VDE0878-B, EN55022-B
and CISPR22-B 10kHz - 30MHz, if the load is not more than 10
cm's away. Tightly parallel tracks or twisted pair wiring to the load
should be used. Long leads to the load could radiate common
mode noise, typically above 20 MHz, back to the input power leads.
Conducted emissions should be checked at a system level.
If the unit fails level B at a frequency greater then 20MHz, because
of system wiring, an additional external ‘Y-capacitor’ could be con-
nected between input ground and output common, to locally
decouple common-mode noise. This capacitor type is usually
intended for use in interference suppression between line and earth.
A recommended capacitor is EVOX-RIFA PME271Y422M or equiva-
lent.
4. Telecom and Distributed Power Architecture
Features
Input Undervoltage Protection:
Internally, the BXA15 and BXA30 series contain an undervoltage
lockout zener circuit. The converter should not be operated continu-
ously at levels between the ‘maximum guaranteed-off-threshold’
and the ‘minimum guaranteed-on-threshold.’
Nominal Input
Voltage
12
24
48
Maximum Off
Voltage
7.0
14
28
Minimum On
Voltage
8.8
17
34
PAGE 1


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for BXA30 electronic component.


Information Total 4 Pages
Link URL [ Copy URL to Clipboard ]
Download [ BXA30.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
BXA3The function is 3W Wide Input DC/DC Converters. Artesyn TechnologiesArtesyn Technologies
BXA3-24S05JThe function is DC-DC / Low Power Isolated Industrial. EmersonEmerson
BXA3-24S05YThe function is DC-DC / Low Power Isolated Industrial. EmersonEmerson

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

BXA3     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search