Current Transducers CT 0.1 .. 0.4-P
For the electronic measurement of small currents: AC,DC, mixed,
with a galvanic isolation between the primary circuit and the
secondary circuit.
IPN = ± 100..400 mA
VOUT = ± 5 V
Electrical data
Primary nominal
current rms
IPN (mA)
100
200
400
Primary current,
measuring range
IPM (mA)
± 180
± 360
± 720
Type
CT 0.1-P
CT 0.2-P
CT 0.4-P
VC
I
C
RIS
V
OUT
ROUT
R
L
CL
Supply voltage (± 5 %)
Current consumption
Isolation resistance @ 500 VDC
Output
voltage
(Analog)
@
±
I
PN,
R=
L
10kΩ,
T =25°C
A
Output internal resistance
Load resistance
Capacitive loading
RoHS since
date code
46129
46054
46234
± 15
± 35
> 500
±5
< 51
≥ 10
≤5
V
mA
MΩ
V
Ω
kΩ
nF
Accuracy-Dynamic performance data
X
εL
TCVOUT
VOE
VOH
TCVOE
tr
BW
Accuracy (excluding offset) @ IPN, TA = 25°C, RL = 10kΩ < ± 1 %of IPN
Linearity error (0 .. ± IPN)
< ± 0.5 %of IPN
Temperature coefficient of VOUT (of reading)
< ± 0.05 %/K
Eletrical offset voltage @ IP = 0, TA = 25°C
< ± 50
mV
Hysteresis offset voltage
@ IP = 0; after an excursion of 1 x IPN
<±2
@ IP = 0; after an excursion of 100 x IPN
< ± 20
Temperature coefficient of VOE @ -20..+85°C CT 0.1-P < ± 4
CT 0.2-P < ± 3
mV
mV
mV/K
mV/K
CT 0.4-P < ± 2 mV/K
Response time to 80% of IPN step
90% of I step
PN
Frequency bandwidth (- 3 dB)
≤ 20
ms
≤ 60
ms
CT 0.1-P DC .. 7000 Hz
CT 0.2-P DC .. 11000 Hz
CT 0.4-P DC .. 18000 Hz
General data
TA Ambient operating temperature
TS Ambient storage temperature
dCp Creepage distance
dCl Clearance distance
CTI Comparative tracking index (Group IIIa)
m Mass
Standards
- 20 .. + 85 °C
- 25 .. + 85 °C
> 5.5
mm
> 5.5
mm
> 220
25 g
EN 50178: 1997
Features
• DC & AC earth leakage current
transducer using a flux-gate
principle
• PCB mounting
• ±15V power supply
•
±5V
output
@
I
PN
• Insulated plastic case recognized
according to UL94-V0.
Advantages
• Small size
• Bandwidth : DC .. up to 18kHz
• Response time better than 60 ms
• Cost effective, compact
alternative to classical RCDs
(Residual Current Device)
Applications
• Earth leakage detection in
transformerless solar inverters
• 1st human contact protection of
PV arrays
• Failure detection in power sources
• Symmetrical fault detection
(e.g. after motor inverter)
• Current leakage detection in
stacked DC sources
• Single phase or three phase
differential current measurement up
to ±30A per wire (DC or AC)
Application Domain
• Industrial
061017/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
copyright protected
Page 1/3
www.lem.com
1 Page Dimensions CT 0.1 .. 0.4-P (in mm. 1 mm = 0.0394 inch)
30
20
11.0
M GND -Vcc+Vcc
M GND -Vcc +Vcc
12.6
1177..88
44--
0.7
0.7
± 0.3
Ip flux-gate
DC
I
22--FØ22 (NC)
± 0.3
+Vcc
transformer
AC
M
GND
Vcc
+Vcc
-+VVcccc
G-VNcDc
20.3
22--ØF55± 0.3
GNMD
M
RL
Vout
Mechanical characteristics
Safety
• General tolerance
± 1 mm
(Unless otherwise specified in the above drawings.)
• Aperture for primary conductor Ø11 mm
• Connection of secondary
4 pins 0.7 x 0.7 mm2
Recommended PCB hole
1.2 mm
• PCB fixation
2 pins Ø2 mm
Recommended PCB hole
2.2 mm
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Remarks
Caution, risk of electrical shock
• VOUT is positive when IP flows in the direction of the
arrow.
• This transducer induces into the primary circuit a
square wave of 500Hz. This voltage can induce an AC
current in the primary if the primary impedance is low.
• Primary impedance ≥10Ω CT0.1-P CT0.2-P CT0.4-P
VOUT by induced current ≤±0.5% ≤±0.4% ≤±0.2% of IPN
• Temperature of the primary conductor should not
exceed 100°C.
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 3/3
061017/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
3Pages | |||
ページ | 合計 : 3 ページ | ||
|
PDF ダウンロード | [ CT0.2-P データシート.PDF ] |
データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。 |
部品番号 | 部品説明 | メーカ |
CT0.2-P | (CT0.1-P - CT0.4-P) Current Transducers | LEM |