DataSheet.es    


PDF LA55-P Data sheet ( Hoja de datos )

Número de pieza LA55-P
Descripción Current Transducer LA 55-P
Fabricantes LEM 
Logotipo LEM Logotipo



Hay una vista previa y un enlace de descarga de LA55-P (archivo pdf) en la parte inferior de esta página.


Total 2 Páginas

No Preview Available ! LA55-P Hoja de datos, Descripción, Manual

www.DataSheet4U.com
Current Transducer LA 55-P
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 50 A
Electrical data
IPN Primary nominal r.m.s. current
I Primary current, measuring range
P
RM Measuring resistance @
50
0 .. ± 70
TA = 70°C TA = 85°C
RR RR
M min M max M min M max
A
A
with ± 12 V
with ± 15 V
@ ± 50 A
max
@ ± 70 A max
@ ± 50 A
max
@ ± 70 A max
10 100 60 95
10 50 601) 601)
50 160 135 155
50 90 13 52) 1352)
ISN Secondary nominal r.m.s. current
K N Conversion ratio
VC Supply voltage (± 5 %)
IC Current consumption
Vd R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
50 mA
1 : 1000
± 12 .. 15
V
10 (@ ±15 V) + IS mA
2.5 kV
Accuracy - Dynamic performance data
X Accuracy @ I , T = 25°C
PN A
@ ± 15 V (± 5 %) ± 0.65
@ ± 12 .. 15 V (± 5 %) ± 0.90
ε Linearity
L
< 0.15
%
%
%
Typ Max
I Offset current @ I = 0, T = 25°C
O PA
± 0.2 mA
IOM Residual current 3) @ IP = 0, after an overload of 3 x IPN
± 0.3 mA
I Thermal drift of I
OT O
0°C .. + 70°C ± 0.1 ± 0.5 mA
- 25°C .. + 85°C ± 0.1 ± 0.6 mA
tra
t
r
di/dt
f
Reaction time @ 10 % of IP max
Response time @ 90 % of I
P max
di/dt accurately followed
Frequency bandwidth (- 1 dB)
< 500
<1
> 200
DC .. 200
ns
µs
A/µ s
kHz
General data
TA Ambient operating temperature
TS Ambient storage temperature
R S Secondary coil resistance @
m Mass
Standards 4)
TA = 70°C
TA = 85°C
- 25 .. + 85
- 40 .. + 90
80
85
18
EN 50178
°C
°C
g
Features
Closed loop (compensated) current
transducer using the Hall effect
Printed circuit board mounting
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Notes : 1) Measuring range limited to ± 60 A
max
2) Measuring range limited to ± 55 A
max
www.D34)) RAaetlisasutSltoofhfcetohreeretcs4opUeornc.dicvineogfmiteeldstsofisthaevmaialagbnleetic circuit
980706/8
LEM Components
w w w .lem.com

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet LA55-P.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
LA55-PCurrent Transducer LA 55-PLEM
LEM
LA55-TPCurrent Transducer LA 55-TPLEM
LEM

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar