Dual Relays
25-40Amp • 120/240, 480 Vac • AC OUTPUT
Zero Voltage and Random
Turn-On Swi tching
SCR Output
Industry Standard Package
Panel M ount
Two totally independent AC output
relays come in a single standard panel-
mount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zero-
voltage or random turn-on (phase con-
trollable) switching.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
MODEL NUMBERS
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms]
Load Current Range [Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (RθJC) [ûC/W]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS
D2425D D2440D
D2425DE D2440DE
H12D4825D
H12D4825DE
24-280
.15-25
600
250
1.6
1.02
260
24-280
.15-40
600
625
1.6
.63
1620
10
500
1/2 cycle
1/2 cycle
0.5
10
500
1/2 cycle
1/2 cycle
0.5
D24XXD
48-530
.15-25
1200
250
1.6
1.02
260
10
500
1/2 cycle
1/2 cycle
0.5
H12D48XXD
H12D4840D
H12D4840DE
48-530
.15-40
1200
625
1.6
.63
1620
10
500
1/2 cycle
1/2 cycle
0.5
E-SUFFIX
Control Voltage Range
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix)
4-15Vdc
4.0 Vdc
1.0 Vdc
300 Ohms
13mA
4-15Vdc
4.0 Vdc
1.0 Vdc
240 Ohms
13mA
15-32Vdc
15 Vdc
1.0 Vdc
1500 Ohms
15mA
GENERAL NOTES
© 2003 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25˚C and per section unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
.comTurn-on time for random turn-on (-10) versions is 0.1 msec.
Crydom Heat Sinks offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom's Heat Sink specifica-
tion sheet for all the details.
atasheet4uFastFax Document No. 165
DUAL.
.dRev. 111203
wwwPAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet H12D4840DE.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
H12D4840D(H12D48xx) Dual RelaysCrydom
Crydom
H12D4840DE(H12D48xx) Dual RelaysCrydom
Crydom

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar