DC005NGC4のメーカーはETCです、この部品の機能は「Ultra Low Pressure Sensors」です。 |
部品番号 | DC005NGC4 |
| |
部品説明 | Ultra Low Pressure Sensors | ||
メーカ | ETC | ||
ロゴ | |||
このページの下部にプレビューとDC005NGC4ダウンロード(pdfファイル)リンクがあります。 Total 12 pages
OCTOBER 1997
SURSENSE™ Ultra Low Pressure Sensors
DCAL4 Series
Ratiometric 4-Volt Output
High Accuracy Compensation
Full Scale Pressure Ranges
0 to 1 in. H2O to 0 to 30 in. H2O
±0 to ±1 in. H2O to ±0 to ±30 in. H2O
DESCRIPTION
The SURSENSE™ line of ultra low pressure sensors is based
upon a proprietary, patent applied for technology designed
to reduce all output offset or common mode errors.
These sensors utilize a silicon, micromachined sensing element
which features a unique stress concentration enhanced
structure to provide a highly stable linear output that is
proportional to applied pressure. Output offset errors due to
changes in temperature, warm-up, long term stability and
position sensitivity have all been significantly reduced when
compared to conventional sensors.
The DCAL series sensors provide a precision calibrated
ratiometric 4 -volt output with SURSENSE enhanced stability.
Each sensor features the precision calibration found in the
DCX series with the addition of fully integrated signal
conditioning in an industry standard package. Intended to
operate from a fixed 5Vdc supply, the DCAL4 gage pressure
sensors provide a 0.25v to 4.25v output while the differential
versions provide a ±2.0 volt output centered on a 2.25 volt
zero pressure offset. These highly stable sensors are ideally
suited for microprocessor or microcontroller based systems.
APPLICATIONS
s Medical Instrumentation
s HVAC
s Environmental Controls
s Portable Monitors
FEATURES
s Available in Gage and Differential
Pressure Ranges
s Temperature Compensated over 0°C to 50°C
s Position Sensitivity to ±5mV/g
s Warm-up drift < ±5mV
s Long Term Stability < ±10mV
s Combined Linearity and Hysteresis Error
< ±0.25%FS
s Custom Calibration Available
EQUIVALENT CIRCUIT
–
+
VEXCITATION (1)
VOUTPUT (3)
VOFFSET (4)
Common (2)
PINOUT
1
2
3
4
VEXCITATION
Common
VOUTPUT
VOFFSET
1 Page DCAL401DN
DCAL Series
SURSENSE™ Ultra Low Pressure Sensors
Ratiometric 4-Volt Output
High Accuracy Compensation
±1 in. H2O Full Scale Pressure
MAXIMUM RATINGS
PARAMETER
Operating Temperature Range
Storage Temperature
Proof Pressure
Burst Pressure
Supply Current
Output Source Current
Output Sink Current
Excitation Voltage
Common Mode Pressure
MINIMUM
–25
–40
100
200
MAXIMUM
85
125
UNITS
°C
°C
in H2O
in H2O
3 16
V
50 psig
ELECTRICAL SPECIFICATIONS
PARAMETER, note 1
Operating Range, differential pressure
Output Span, note 2
Offset Voltage @ zero differential pressure
Temperature Effect on Offset (0°C–50°C), note 3
Combined Temperature Effect on Span (0°C–50°C),
note 3
Offset Warm-up Shift, note 4
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Combined Linearity and Hysteresis Error, note 5
MINIMUM
±1.90
2.15
NORMAL
±1.0
±2.0
2.25
MAXIMUM
±2.10
2.35
±40
±2
±20
±10
±10
0.05 0.25
Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 5VDC, TA = 25°C, Common Mode Line Pressure = 0 psig.
Pressure measurements are with pressure applied to Port B.
Note 2: The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 0.25 to 4.25 volts.
Note 3: Shift is relative to 25°C.
Note 4: Shift is within the first hour of excitation applied to the device.
Note 5: Measured at one-half full scale rated pressure using best straight line curve fit.
UNITS
in. H2O
V
V
mV
%Span
mV
mV
mV
%FS
3Pages DCAL Series
SURSENSE™ Ultra Low Pressure Sensors
DCAL410GN
Ratiometric 4-Volt Output
High Accuracy Compensation
10 in. H2O Full Scale Pressure
MAXIMUM RATINGS
PARAMETER
Operating Temperature Range
Storage Temperature
Proof Pressure
Burst Pressure
Output Source Current
Output Sink Current
Excitation Voltage
Common Mode Pressure
MINIMUM
–25
–40
150
300
MAXIMUM
85
125
UNITS
°C
°C
in. H2O
in. H2O
3 16
V
50 psig
ELECTRICAL SPECIFICATIONS
PARAMETER, note 1
Operating Pressure Range, gage pressure
Output Span, note 2
Offset Voltage
Temperature Effect on Offset (0°C–50°C), note 3
Combined Temperature Effect on Span (0°C–50°C),
note 3
Offset Warm-up shift, note 4
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Combined Linearity and Hysteresis Error, note 5
MINIMUM
3.9
0.15
NORMAL
10.0
4.0
0.25
±3
MAXIMUM
4.1
0.35
±20
±1
±5
±1
±10
0.05 0.25
Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 5VDC, TA = 25°C, Common Mode Line Pressure = 0 psig.
Pressure measurements are with pressure applied to Port B.
Note 2: The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 0.25 to 4.25 volts.
Note 3: Shift is relative to 25°C.
Note 4: Shift is within the first hour of excitation applied to the device.
Note 5: Measured at one-half full scale rated pressure using best straight line curve fit.
UNITS
in. H2O
V
V
mV
%Span
mV
mV
mV
%FS
6 Page | |||
ページ | 合計 : 12 ページ | ||
|
PDF ダウンロード | [ DC005NGC4 データシート.PDF ] |
データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。 |
部品番号 | 部品説明 | メーカ |
DC005NGC4 | Ultra Low Pressure Sensors | ETC |