New Features
• Monitor Voltages: 5V to 0.9V
• Independent Core Voltage Monitor
Preliminary Datasheet
X40010/X40011/X40014/X40015
Dual Voltage Monitor with Integrated CPU Supervisor
FEATURES
• Dual voltage detection and reset assertion
—Standard reset threshold settings
See Selection table on page 2.
—Adjust low voltage reset threshold voltages
using special programming sequence
—Reset signal valid to VCC = 1V
—Monitor three voltages or detect power fail
• Independent Core Voltage Monitor (V2MON)
• Fault detection register
• Selectable power on reset timeout (0.05s,
0.2s, 0.4s, 0.8s)
• Selectable watchdog timer interval (25ms, 200ms,
1.4s, off)
• Low power CMOS
—25µA typical standby current, watchdog on
—6µA typical standby current, watchdog off
• 400kHz 2-wire interface
• 2.7V to 5.5V power supply operation
• Available packages
—8-lead SOIC, TSSOP
APPLICATIONS
• Communication Equipment
—Routers, Hubs, Switches
—Disk Arrays, Network Storage
• Industrial Systems
—Process Control
—Intelligent Instrumentation
• Computer Systems
— Computers
—Network Servers
DESCRIPTION
The X40010/11/14/15 combines power-on reset con-
trol, watchdog timer, supply voltage supervision, and
secondary voltage supervision, in one package. This
combination lowers system cost, reduces board space
requirements, and increases reliability.
Applying voltage to VCC activates the power on reset
circuit which holds RESET/RESET active for a period of
time. This allows the power supply and system oscillator
to stabilize before the processor can execute code.
Low VCC detection circuitry protects the user’s system
from low voltage conditions, resetting the system when
VCC falls below the minimum VTRIP1 point. RESET/
RESET is active until VCC returns to proper operating
level and stabilizes. A second voltage monitor circuit
tracks the unregulated supply to provide a power fail
warning or monitors different power supply voltage.
Three common low voltage combinations are avail-
able, however, Xicor’s unique circuits allows the
BLOCK DIAGRAM
SDA
SCL
VCC
(V1MON)
V2MON
Data
Register
Command
Decode Test
& Control
Logic
Threshold
Reset Logic
Fault Detection
Register
Status
Register
Watchdog Timer
and
Reset Logic
User Programmable
VTRIP1
User Programmable
VTRIP2
+
-
V2MON
+ VCC
Power on,
Low Voltage
Reset
Generation
-
*X40010/11 = V2MON*
X40014/15 = VCC
WDO
RESET
X40010/14
RESET
X40011/15
V2FAIL
REV 1.3.4 7/12/02
www.xicor.com
Characteristics subject to change without notice. 1 of 25

1 Page





X40010 pdf, ピン配列
X40010/X40011/X40014/X40015 – Preliminary
PIN DESCRIPTION (Continued)
Pin
SOIC TSSOP
57
68
71
82
Name
SDA
SCL
WDO
VCC
Function
Serial Data. SDA is a bidirectional pin used to transfer data into and out of the device. It has an
open drain output and may be wire ORed with other open drain or open collector outputs. This pin
requires a pull up resistor and the input buffer is always active (not gated).
Watchdog Input. A HIGH to LOW transition on the SDA (while SCL is toggled from HIGH to
LOW and followed by a stop condition) restarts the Watchdog timer. The absence of this tran-
sition within the watchdog time out period results in WDO going active.
Serial Clock. The Serial Clock controls the serial bus timing for data input and output.
WDO Output. WDO is an active LOW, open drain output which goes active whenever the
watchdog timer goes active.
Supply Voltage
PRINCIPLES OF OPERATION
Power On Reset
Application of power to the X40010/11/14/15 activates a
Power On Reset Circuit that pulls the RESET/RESET
pins active. This signal provides several benefits.
– It prevents the system microprocessor from starting to
operate with insufficient voltage.
– It prevents the processor from operating prior to stabili-
zation of the oscillator.
– It allows time for an FPGA to download its configuration
prior to initialization of the circuit.
– It prevents communication to the EEPROM, greatly
reducing the likelihood of data corruption on power up.
When VCC exceeds the device VTRIP1 threshold value for
tPURST (selectable) the circuit releases the RESET
(X40011) and RESET (X40010) pin allowing the system
to begin operation.
Low Voltage VCC (V1 Monitoring)
During operation, the X40010/11/14/15 monitors the VCC
level and asserts RESET/RESET if supply voltage falls
below a preset minimum VTRIP1. The RESET/RESET
signal prevents the microprocessor from operating in a
power fail or brownout condition. The V1FAIL signal
remains active until the voltage drops below 1V. It also
remains active until VCC returns and exceeds VTRIP1 for
tPURST.
Low Voltage V2 Monitoring
The X40010/11/14/15 also monitors a second voltage
level and asserts V2FAIL if the voltage falls below a
preset minimum VTRIP2. The V2FAIL signal is either
ORed with RESET to prevent the microprocessor from
operating in a power fail or brownout condition or used to
interrupt the microprocessor with notification of an
impending power failure. For the X40010/11 the V2FAIL
signal remains active until the VCC drops below 1V (VCC
falling). It also remains active until V2MON returns and
exceeds VTRIP2 by 0.2V. This voltage sense circuitry
monitors the power supply connected to the V2MON pin.
If VCC = 0, V2MON can still be monitored.
For the X40014/15 devices, the V2FAIL signal remains
actice until VCC drops below 1Vx and remains active until
V2MON returns and exceeds VTRIP2. This sense circuitry
is powered by VCC. If VCC = 0, V2MON cannot be moni-
tored.
Figure 1. Two Uses of Multiple Voltage Monitoring
X40011-A
VCC V2MON
6–10V
1M
1M
5V VCC
Reg RESET
V2MON
(2.9V)
V2FAIL
System
Reset
Resistors selected so 3V appears on V2MON when unregulated
supply reaches 6V.
Unreg.
Supply
3.3V
Reg
1.2V
Reg
X40014-C
VCC
VCC
RESET
V2MON
V2FAIL
System
Reset
Notice: No external components required to monitor two voltages.
REV 1.3.4 7/12/02
www.xicor.com
Characteristics subject to change without notice. 3 of 25


3Pages


X40010 電子部品, 半導体
X40010/X40011/X40014/X40015 – Preliminary
Figure 5. VTRIPX Set/Reset Sequence (X = 1, 2)
VTRIPX Programming
No Desired
VTRIPX
Present Value
YES
Execute
VTRIPX Reset Sequence
New VX applied =
Old VX applied + | Error |
NO
Execute
Set Higher VTRIPX Sequence
Execute
Set Higher VX Sequence
Apply VCC and Voltage
> Desired VTRIPX to VX
Decrease VX
Vx = VCC, VxMON
Note: X = 1, 2
Let: MDE = Maximum Desired Error
MDE+
Desired Value
MDE
Acceptable
Error Range
Error = Actual - Desired
New VX applied =
Old VX applied - | Error |
Execute Reset VTRIPX
Sequence
Error < MDE
Output Switches?
YES
Actual VTRIPX -
Desired VTRIPX
Error > MDE+
| Error | < | MDE |
DONE
WEL: Write Enable Latch (Volatile)
The WEL bit controls the access to the memory and to
the Register during a write operation. This bit is a vola-
tile latch that powers up in the LOW (disabled) state.
While the WEL bit is LOW, writes to any address,
including any control registers will be ignored (no
acknowledge will be issued after the Data Byte). The
WEL bit is set by writing a “1” to the WEL bit and zeros
to the other bits of the control register.
Once set, WEL remains set until either it is reset to 0
(by writing a “0” to the WEL bit and zeros to the other
bits of the control register) or until the part powers up
again. Writes to the WEL bit do not cause a high volt-
age write cycle, so the device is ready for the next
operation immediately after the stop condition.
REV 1.3.4 7/12/02
www.xicor.com
Characteristics subject to change without notice. 6 of 25

6 Page



ページ 合計 : 25 ページ
 
PDF
ダウンロード
[ X40010 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
X40010

Dual Voltage Monitor with Integrated CPU Supervisor

Xicor
Xicor
X40010S8-A

Dual Voltage Monitor with Integrated CPU Supervisor

Xicor
Xicor
X40010S8-B

Dual Voltage Monitor with Integrated CPU Supervisor

Xicor
Xicor
X40010S8-C

Dual Voltage Monitor with Integrated CPU Supervisor

Xicor
Xicor


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap