DataSheet.jp

EWD505 の電気的特性と機能

EWD505のメーカーはPower-Oneです、この部品の機能は「DUAL OUTPUT/ 5 WATT」です。


製品の詳細 ( Datasheet PDF )

部品番号 EWD505
部品説明 DUAL OUTPUT/ 5 WATT
メーカ Power-One
ロゴ Power-One ロゴ 




このページの下部にプレビューとEWD505ダウンロード(pdfファイル)リンクがあります。

Total 3 pages

No Preview Available !

EWD505 Datasheet, EWD505 PDF,ピン配置, 機能
(888) IPD-CONVerters q (888) 473-2668 q www.ipdconverters.com
EWD SERIES - DUAL OUTPUT, 5 WATT
DESCRIPTION
FEATURES
EWD dual output DC/DC converters offer excellent • Industry Standard Package • 5V and 12V Inputs
regulation and isolation in an industry standard
• Industry Standard Pinout • Input Pi Filter
package. Available in several input versions, the EWD • 85°C Case Operation
is perfect for industrial, datacom, or telecom
applications. The EWD features short circuit
• Short Circuit Protection
protection, six-sided shielding, and 500 VDC isolation.
• 6-Sided Shielding
• Regulated Outputs
• 500V Isolation
Please see the EWS series for single output
applications.
Efficiency vs. Load (5V Input)
TECHNICAL SPECIFICATIONS
Voltage Range
5V DC Nominal
12 VDC Nominal
Reflected Ripple
Reverse Input Current
Input
Output
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Temperature Coefficient
Ripple and Noise, 20 MHz BW
Short Circuit Protection 1
Current Limit
4.5 - 9 VDC
9 - 18 VDC
20% Iin Max.
100% Iin Max.
±1%
±1.0% Vout
±1.0% Vout
10 % Iout Rated
25% Iout
1% Vout
500 µs
0.02%/°C
1% Vout Nom.
Hiccup
130%
90
85
80
75
70 EFF. (505)
65 EFF. (512)
EFF. (515)
60
55
50
10 20 30 40 50 60 70 80 90 100
LOAD %
Efficiency vs. Load (12V Input)
90
85
80
75
70
65
EFF. EWS1212
60
EFF. EWS1215
55
50
45
10 20 30 40 50 60 70 80 90 10
LOAD %
General
Switching Frequency
Isolation
Input - Output
Isolation Resistance - Input to Output
Standard Case Operating Range
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min. each
Safety
Weight (Approx.)
200 kHz
500 VDC
109 Ohms
-25 To +85°C
-40 To +125°C
95%
5 g, 10 - 55 Hz
UL, CUL, TUV
1.4 oz
Notes
1 Converter will auto-restart once fault has been removed.
Specifications typically at 25°C, normal line, and full load unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult
factory
for specific model information.
C-66

1 Page





EWD505 pdf, ピン配列
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
Negative Logic
Lucent Compatible Trim
Terminal Strip
Trim
Enable
Trim and Enable
Current Share
Headerless
SUFFIX
APPLICABLE SERIES
N HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
T HAS, HBD, HBS, HES, QBS, QES
TS XWS, XWD, XWT
1 IAS, LES
2 IAD, IAS, LES, SMS
3 IAS, LES
4 SMS
Y Encapsulated EWS, IWS, OWS
REMARKS
TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
PIN LENGTH AND HEATSINK
OPTIONS
0.110” (2.8mm) Pin Length
0.150” (3.8mm) Pin Length
0.24” (6.1mm) Horizontal Heatsink
0.24” (6.1mm) Vertical Heatsink
0.45” (11.4mm) Horizontal
Heatsink
0.45” (11.4mm) Vertical Heatsink
0.95” (24.1mm) Horizontal
Heatsink
0.95” (24.1mm) Vertical Heatsink
Standard Pin Length is 0.180”
(4.6mm)
8 All Units (Except SMS)
9 All Units (Except SMS)
1H All Units (Except DIP, SIP, and SM Includes Thermal Pad
Packages)
1V All Units (Except DIP, SIP, and SM Includes Thermal Pad
Packages)
2H All Units (Except DIP, SIP, and SM Includes Thermal Pad
Packages)
2V All Units (Except DIP, SIP, and SM Includes Thermal Pad
Packages)
3H All Units (Except DIP, SIP, and SM Includes Thermal Pad
Packages)
3V All Units (Except DIP, SIP, and SM Includes Thermal Pad
Packages)
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
C105


3Pages





ページ 合計 : 3 ページ
 
PDF
ダウンロード
[ EWD505 データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
EWD505

DUAL OUTPUT/ 5 WATT

Power-One
Power-One


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap