20 Watt | AC-DC / DC-DC Converter
I/O Isolation 3000VAC
Operating Temp: -40 oC to +80 oC
Over load and, Over Voltage Protection
Input: 90-305VAC, 47-440Hz, or 130-430VDC
Energy Star compliant
Ultra small package
Up to 81% efficiency
Short Circuit Protection
Models
Single output
CB 
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max
Output
wattage
(W)
Output
Voltage(V)
Output
Current
max (A)
Maximum
capacitive
load (µF)
Efficiency
(%)
115 230 277
VAC
VAC
VAC
AMEL20-3.3SAZ 90-305/47-440 130-430
13.2
3.3
4
5600
73 73 72
AMEL20-5SAZ
90-305/47-440 130-430
20
5
4
4700
77 77 76
AMEL20-12SAZ
90-305/47-440 130-430
20
12
1.66
3300
80 80 80
AMEL20-15SAZ
90-305/47-440 130-430
20
15
1.33
2200
81 80 80
AMEL20-24SAZ
90-305/47-440 130-430
20
24
0.84
1000
79 80 79
Note: Optional mounting plate version can be order by adding “-ST” suffix to part number (ex. AMEL20-5SMAZ-ST)
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
Recommended slow blow type
(115/230/277 VAC)
Typical
1.5
0.5
150
Maximum
460
290
260
30
50
55
0.25
Units
mA
mA
mA
A
A
A
mA
A
W
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Transient recovery time
Transient response deviation
Ripple & Noise*
Hold-up time
Conditions
(LL-HL)
0-100% load
25% load step
Typical
±2
±1
±2
500
±2
200
10
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) and 47µF (E/C) parallel capacitor.
Maximum
Units
%
%
%
µs
% of Vout
mV p-p
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
60 sec
Typical
>1000
Rated
3000
Units
VAC
M
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
Conditions
Foldback
Typical
65
130
Zener Diode Clamp
Maximum
Units
KHz
%
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only

1 Page





AMEL20-AZ pdf, ピン配列
Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
Additional Surge Protective Circuitry
The AMEL20-AZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However
greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal
Oxide Varistor) device example S14K320E2 to the N / L input lines 2KV surge protection or greater, can be achieved.
MOV PN
S14K320E2
Vrms
V
320
Pin Out Specifications
Pin Single
1 AC Input (N)
2 AC Input (L)
3 +V Output
4 -V Output
5 No pin
Derating
Vdc
Wmax (2ms)
Pmax
V JW
420 136 0.6
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only


3Pages





ページ 合計 : 5 ページ
 
PDF
ダウンロード
[ AMEL20-AZ データシート.PDF ]


データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。


共有リンク

Link :


部品番号部品説明メーカ
AMEL20-AZ

AC-DC / DC-DC Converter

AIMTEC
AIMTEC


www.DataSheet.jp    |   2020   |  メール    |   最新    |   Sitemap