6RA70 Series Base Drive Instruction Manual
Microprocessor-based converters from 15A -1680A
for variable speed DC drives
Rev 7.0
dc drives

1 Page



6RA7013-2FV62-0 pdf, ピン配列
8 Start-up
8.1 General safety information
8.2 Operator control panels
8.3 Parameterization procedure
8.4 Typical connection diagrams
8.5 Reset to factory default values
8.6 Start-up procedure
8-1
8-2
8-4
8-6
8-8
8-9
9 Faults and Alarms
9.1 Fault messages
9.2 Alarm messages
9-1
9-28
10 Abbreviated Parameter List
Overview
Overview of Abbreviations
10.1 Operating Status Display
10.2 General Visualization Parameters
10.3 Access Authorization Levels
10.4 Definition of SIMOREG Converter
10.5 Setting Values for Converter Control
10.6 Definition of Motor
10.7 Definition of Speed Sensing Pulse Encoder
10.8 Armature Current Control, Reversing, Gating
10.9 Current/Torque Limitation
10.10 Auto-reserving stage. Armature gating unit
10.11 Speed Controller
10.12 Field Current Control, Gating
10.13 Closed Loop EMF Control
10.14 Ramp Function Generator
10.15 Setpoint Processing
10.16 Ramp Function generator
10.17 Monitoring Functions and Limits
10.18 Limit-Value Monitors
10.19 Settable fixed values
10.20 Fixed control bits
10.21 Digital Setpoint Inputs
10.22 Position sensing with pulse encoder
10.23 Connector selector switches
10-1
10-3
10-5
10-7
10-11
10-13
10-17
10-22
10-27
10-30
10-32
10-34
10-34
10-36
10-38
10-39
10-41
10-42
10-42
10-43
10-45
10-46
10-46
10-48
10-49
0-2
Siemens Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions


3Pages


6RA7013-2FV62-0 電子部品, 半導体
1 Safety information
WARNING
Hazardous voltages and rotating parts are present in this electrical equipment during
operation. Non-observance of the safety instructions can result in death, severe
personal injury or substantial property damage.
Only qualified personnel should work on or around the equipment after first becoming
thoroughly familiar with all warning and safety notices and maintenance procedures contained
herein. The successful and safe operation of this equipment is dependent on proper handling,
installation, operation and maintenance.
Definitions:
x QUALIFIED PERSONNEL
For the purpose of this Instruction Manual and product labels, a "Qualified Person" is someone who
is familiar with the installation, construction and operation of the equipment and the hazards
involved. He or she must have the following qualifications:
1. Trained and authorized to energize, de-energize, clear, ground and tag circuits and equipment in
accordance with established safety procedures.
2. Trained in the proper care and use of protective equipment in accordance with established
safety procedures.
3. Trained in providing first aid.
x DANGER
For the purpose of this Instruction Manual and product labels, "Danger" indicates that death,
severe personal injury or substantial property damage will result if proper precautions are not
taken.
x WARNING
For the purpose of this Instruction Manual and product labels, "Warning" indicates that death,
severe personal injury or substantial property damage can result if proper precautions are not
taken.
x CAUTION
For the purpose of this Instruction Manual and product labels, "Caution" indicates that minor
personal injury or property damage can result if proper precautions are not taken.
x NOTE
For the purpose of this Instruction Manual, "Note" indicates information about the product or the
respective part of the Instruction Manual which requires particular attention.
Siemens Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
1-1

6 Page





ページ 合計 : 30 ページ
PDF
ダウンロード
[ 6RA7013-2FV62-0.PDF ]

共有リンク

Link :

おすすめデータシート

部品番号部品説明メーカ
6RA7013-2FV62-0

There is a function of dc drives Instruction Manual.

Siemens
Siemens

多くを見つけるデータシート

部品番号部品説明メーカ
82S129

The 82S126 and 82S129 are field programmable, which means that custom patterns are immediately available by following the Signetics Generic fusing procedure. 1K-bit TTL Bipolar PROM, Address access time : 50ns max.

NXP
NXP
D1695

This part is a darlington connection NPN silicon epitaxial transistor. The 2SD1695 is a Darlington connection transistor and incorporates a dumper diode between the collector and emitter and a constant voltage diode and protection elements between the collector and base. This transistor is ideal for drives in solenoid and actuators.

NEC
NEC

www.DataSheet.jp    |   2018   |  メール    |   最新    |   Sitemap