Designed With Machine Automation in Mind
• Current vector control
• High starting torque: 200% at 0.5Hz
• Double rating VT 120%/1min and CT 150%/1min
• Speed range up to 1000 Hz
• IM & PM motor control
• Torque control in open loop vector
• Positioning functionality
• Built-in application functionality (i.e. Brake control)
• User programmable as standard
• Safety embedded compliant with ISO13849-1 (double input
circuit and external device monitor EDM)
• USB port for PC programming
• 24 VDC backup supply for control board
• Fieldbus communications: Modbus, DeviceNet, Profibus,
Componet, Ethercat, ML-II and CanOpen
• PC configuration tool: CX-Drive
• RoHS, CE, cULus
Ratings
• 200 V Class single-phase 0.2 to 2.2 kW (1/8 to 3.0 HP)
• 200 V Class three-phase 0.2 to 15.0 kW (1/8 to 20 HP)
• 400 V Class three-phase 0.4 to 15.0 kW (1/2 to 20 HP)
System configuration
Power
Supply
MCCB
Input AC Reactor
Filter
USB Cable
Remote Operator
Extansion Cable
CX-Drive
CX-One
LCD 5 lines
Remote Operator
Communication Option Board
3G3MX2
Choke
Motor
Ground
Braking Resistor
DC Reactor
Output AC Reactor
8 Frequency inverters
Free Datasheet http://www.Datasheet4U.com

1 Page





3G3MX2 pdf, ピン配列
Specifications
Commom specifications
Model number
3G3MX@
Specifications
Control methods
Phase-to-phase sinusoidal pulse with modulation PWM (Sensorless vector control, close loop vector with motor feedback,
V/F)
Output frequency range
0.10..1000.00 Hz (with restrictions above 400Hz)
Frequency precision
Digital set value: ±0.01% of the max. frequency
Analogue set value: ±0.2% of the max. frequency (25 ±10 ºC)
Digital set value: 0.01 Hz
Resolution of frequency set value Analogue set value: 1/1000 of maximum frequency
Resolution of output frequency 0.01Hz
Starting torque
200% / 0.5Hz
Overload capability
Dual rating:
Heavy duty (CT): 150% for 1 minute
Normal Duty (VT): 120% for 1 minute
Frequency set value
0 to 10 VDC (10KΩ), 4 to 20mA (100Ω), RS485 Modbus, Network options
V/f Characteristics
Constant/ reduced torque, free V/f
Inputs signals
FW (forward run command), RV (reverse run command), CF1~CF4 (multi-stage speed setting), JG (jog command), DB (ex-
ternal braking), SET (set second motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external
trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), AT (analog input selection), RS (reset), PTC
(thermistor thermal protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (re-
mote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control),
SF1~SF7 (multi-stage speed setting; bit operation), OLR (overload restriction), TL (torque limit enable), TRQ1 (torque limit
changeover1), TRQ2 (torque limit changeover2), BOK (Braking confirmation), LAC (LAD cancellation), PCLR (position devi-
ation clear), ADD (add frequency enable), F-TM (force terminal mode), ATR (permission of torque command input), KHC (Cu-
mulative power clear), MI1~MI7 (general purpose inputs for EzSQ), AHD (analog command hold), CP1~CP3 (multistage-
position switches), ORL (limit signal of zero-return), ORC (trigger signal of zero-return), SPD (speed/position changeover),
GS1~GS2 (STO inputs, safety related signals), 485 (Starting communication signal), PRG (executing EzSQ program), HLD
(retain output frequency), ROK (permission of run command), EB (rotation direction detection of B-phase), DISP (display lim-
itation), OP (option control signal), NO (no function)
Output signals
RUN (run signal), FA1~FA5 (frequency arrival signal), OL,OL2 (overload advance notice signal), OD (PID deviation error sig-
nal), AL (alarm signal), OTQ (over/under torque threshold), UV (under-voltage), TRQ (torque limit signal), RNT (run time ex-
pired), ONT (power ON time expired), THM (thermal warning), BRK (brake release), BER (brake error), ZS (0Hz detection),
DSE (speed deviation excessive), POK (positioning completion), ODc (analog voltage input disconnection), OIDc (analog
current input disconnection), FBV (PID second stage output), NDc (network disconnect detection), LOG1~LOG3 (Logic out-
put signals), WAC (capacitor life warning), WAF (cooling fan warning), FR (starting contact), OHF (heat sink overheat warn-
ing), LOC (Low load), MO1~MO3 (general outputs for EzSQ), IRDY (inverter ready), FWR (forward operation), RVR (reverse
operation), MJA (major failure), WCO (window comparator O), WCOI (window comparator OI), FREF (frequency command
source), REF (run command source), SETM (second motor in operation), EDM (STO (safe torque off) performance monitor),
OP (option control signal), NO (no function)
Free-V/f, manual/automatic torque boost, output voltage gain adjustment, AVR function, reduced voltage start, motor data
selection, auto-tuning, motor stabilization control, reverse running protection, simple position control, simple torque control,
torque limiting, automatic carrier frequency reduction, energy saving operation, PID function, non-stop operation at
Standard functions
instantaneous power failure, brake control, DC injection braking, dynamic braking (BRD), frequency upper and lower
limiters, jump frequencies, curve accel and decel (S, U, inversed U,EL-S), 16-stage speed profile, fine adjustment of start
frequency, accel and decel stop, process jogging, frequency calculation, frequency addition, 2-stage accel/decel, stop mode
selection, start/end freq., analog input filter, window comparators, input terminal response time, output signal delay/hold
function, rotation direction restriction, stop key selection, software lock, safe stop function, scaling function, display
restriction, password function, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry,
frequency pull-in restart, frequency matching, overload restriction, over current restriction, DC bus voltage AVR
Analogue inputs
2 analogue inputs 0 to 10V (10KΩ), 4 to 20mA (100Ω)
Pulse train input terminal
0 to 10V (up to 24V), up to 32KHz
Accel/Decel times
0.01 to 3600.0s (line/curve selection), 2nd accel/decel setting available
Display
Status indicator LED’s Run, Program, Alarm, Power, Hz, Amps
Digital operator: Available to monitor 32 items: frequency reference, output current, output frequency...
Motor overload protection
Electronic Thermal overload relay and PTC thermistor input
Instantaneous overcurrent
200% of rated current
Overload
Dual rating:
Heavy duty (CT): 150% for 1 minute
Normal Duty (VT): 120% for 1 minute
Overvoltage
800V for 400V type and 400V for 200V type
Undervoltage
345V for 400V type and 172.5V for 200V type
Momentary power loss
Following items are selectable: Alarm, decelerates to stop, decelerates to stop with DC bus controlled, restart
Cooling fin overheat
Temperature monitor and error detection
Stall prevention level
Stall prevention during acceleration/deceleration and constant speed
Ground fault
Detection at power-on
Power charge indication
On when power is supplied to the control part
Degree of protection
IP20, Varnish coating on PCB
Ambient humidity
90% RH or less (without condensation)
Storage temperature
-20 ºC..+65 ºC (short-term temperature during transportation)
Ambient temperature
10°C to 40°C
Installation
Indoor (no corrosive gas, dust, etc.)
Installation height
Vibration
Max. 1000 m
5.9 m/s2 (0.6G), 10 to 55 Hz
10
Frequency inverters
Free Datasheet http://www.Datasheet4U.com


3Pages


3G3MX2 電子部品, 半導体
Voltage
400V
Reference
AX-RAO16300038-DE
AX-RAO11800053-DE
AX-RAO07300080-DE
AX-RAO04600110-DE
AX-RAO03600160-DE
AX-RAO02500220-DE
AX-RAO02000320-DE
A
120
120
120
180
180
180
180
Dimensions in mm
B2 C2 D E F
70 120 80 52 5.5
80 120 80 52 5.5
80 120 80 62 5.5
85 190 140 55 6
85 205 140 55 6
95 205 140 55 6
105 205 140 85 6
Weight
Kg
1.78
2.35
2.35
5.5
6.5
9.1
11.7
Chokes 3G3AX-FEJ
Reference
D
diameter
AX-FEJ2102-RE
AX-FEJ2515-RE
AX-FEJ5045-RE
21
25
50
Motor
KW
< 2.2
< 15
< 45
Dimensions in mm
LWH X Ym
85 22 46 70 - 5
105 25 62 90 - 5
150 50 110 125 30 5
Weight
Kg
0.1
0.2
0.7
WY
H
X
L
Ød
Øm
Resistor Dimensions 3G3AX-REM
AX-REM00K1200
Fig 1
Fig 2
Fig 3
Fig 4
Type
AX-REM00K1400-IE
AX-REM00K2070-IE
AX-REM00K2120-IE
AX-REM00K2200-IE
AX-REM00K4075-IE
AX-REM00K4035-IE
AX-REM00K4030-IE
AX-REM00K5120-IE
AX-REM00K6100-IE
AX-REM00K6035-IE
AX-REM00K9070-IE
AX-REM00K9017-IE
AX-REM01K9070-IE
AX-REM01K9017-IE
AX-REM02K1070-IE
AX-REM02K1017-IE
AX-REM03K5035-IE
AX-REM03K5010-IE
3G3MX2
Fig.
1
2
3
4
Dimensions in mm
L HM I
105 27 36 94
Weight
T KG
- 0.2
200 27
36 189
- 0.425
260 27 36 249 - 0.58
320 27 36 309 - 0.73
200 62 100 74
- 1.41
365 73 105 350 70
4
310 100 240 295 210
7
365 100 240 350 210
8
13
Free Datasheet http://www.Datasheet4U.com

6 Page

合計 : 13 ページ
PDF ダウンロード

[ 3G3MX2 データシート.PDF ]

データシートを活用すると、その部品の主な機能と仕様を詳しく理解できます。 ピン構成、電気的特性、動作パラメータ、性能を確認してください。

scroll


部品番号部品説明メーカ
3G3MX2

Current vector control

Omron
Omron

www.DataSheet.jp     

|     2020   |  メール    |

    最新        |     Sitemap